Improved Outcomes for Transscleral Cyclophotocoagulation Through Optimized Treatment Parameters.

Quigley Harry A

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

PURPOSE: To compare outcomes of transscleral diode cyclophotocoagulation with the treatment parameters used.

PATIENTS AND

METHODS

This was a retrospective chart review of a random, 50% sample of diode procedures using the G-probe over 10 years for uncontrolled glaucoma. The main outcome measure was intraocular pressure (IOP) reduction by 20% and final IOP≤21 mm Hg.

RESULTS

In 236 eyes (persons) treated by 5 glaucoma specialists, most eyes had severe glaucoma, with 75% having <20/200 acuity. Median follow-up was 2.7 years. In eyes receiving only 1 treatment, IOP success criterion was met in 72% (129/180). Success was significantly related to power per delivery and median total joules per treatment (successes=135 J, failures=98 J; P=0.0009), but not to number of deliveries, nor to extent of circumference treated. Greater success was associated with 3 or 4 second duration per delivery, power level based on audible cues, and firm pressure on the sclera. Using a standard 2000 mW, 2 seconds, 20 deliveries in each eye had the lowest success (49%). Of those with no preoperative pain, 40 persons (57%) had no postoperative pain, whereas 20 reported pain of 1-3/10 (29%). Phthisis occurred in 7 eyes (3%), 5 of which had severe secondary eye disease. Nine eyes had no light perception preoperatively, whereas 50 eyes were no light perception at last follow-up, many after additional surgeries for other conditions.

CONCLUSIONS

Diode cyclophotocoagulation achieved reasonable IOP lowering, often without severe postoperative pain or complication. Greater success was achieved when audible effects were used to tailor the power settings to individual responses. Diode treatments with no intraoperative effect adjustment or using standardized protocols may not achieve optimal success.

Для цитирования: Quigley Harry A. Improved Outcomes for Transscleral Cyclophotocoagulation Through Optimized Treatment Parameters.. Journal of glaucoma. 2018. DOI: 10.1097/ijg.0000000000001008.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.