MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jcrs.2009.08.013

Медицинская библиотека · Journal of cataract and refractive surgery · 2009

Visual function after bilateral implantation of apodized diffractive aspheric multifocal intraocular lenses with a +3.0 D addition.

Kohnen Thomas, Nuijts Rudy, Levy Pierre, Haefliger Eduard, Alfonso José F

Клиническое исследованиеСтатьяМногоцентровое исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

PURPOSE: To evaluate visual function after bilateral implantation of apodized diffractive aspheric multifocal intraocular lenses (IOLs) with a +3.0 diopter addition (add) power.

SETTING

Multicenter study at 5 European sites.

METHODS

Five surgeons prospectively enrolled patients to receive bilateral implantation of AcrySof IQ ReSTOR SN6AD1 IOLs. Assessments included defocus testing, uncorrected and corrected distance visual acuities at various distances, and patient questionnaires.

RESULTS

Ninety-three patients were enrolled. The mean distance-corrected visual acuities at far, intermediate, and near distances were significantly better postoperatively. At 6 months, uncorrected visual acuity (logMAR) was -0.03 +/- 0.13 (SD) at 4 m, 0.20 +/- 0.14 at 70 cm, 0.13 +/- 0.15 at 60 cm, 0.05 +/- 0.18 at 50 cm, and 0.04 +/- 0.11 at 40 cm. The mean patient-preferred near distance was 41 +/- 4 cm, at which distance the mean visual acuity was -0.01 +/- 0.11 logMAR. The defocus curve had a plateau of optimum near vision from 40 to 50 cm. Postoperatively, patients reported having minimal to no difficulty with 22 of 27 visual disturbances or visual activities; the other 5 items were ranked minimally to moderately difficult. The mean patient satisfaction with vision was 8.3 +/- 1.6 (out of 10); 88% of patients were spectacle independent.

CONCLUSIONS

Bilateral apodized diffractive aspheric multifocal IOLs with a +3.0 D add provided a broad range of optimum near vision, good intermediate visual acuity, and low rates of visual disturbances. Patients were highly satisfied with their vision, and 88% were spectacle independent.

Для цитирования: Kohnen Thomas, Nuijts Rudy, Levy Pierre, Haefliger Eduard, Alfonso José F. Visual function after bilateral implantation of apodized diffractive aspheric multifocal intraocular lenses with a +3.0 D addition.. Journal of cataract and refractive surgery. 2009. DOI: 10.1016/j.jcrs.2009.08.013.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.