MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/1553350613492587

Медицинская библиотека · Surgical innovation · 2013

A new technique for laparoscopic splenectomy and azygoportal disconnection.

Jiang Guoqing, Qian Jianjun, Yao Jie, Wang Xiaodong, Jin Shengjie, Bai Dousheng

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Laparoscopic splenectomy and azygoportal disconnection (LSD) using many different surgical techniques has become increasingly popular for treatment of cirrhotic patients with bleeding portal hypertension and secondary hypersplenism. Surgical procedures with the least possible impairment are consistently expected by both surgeons and patients. Here, we report a clinical cohort of 10 patients who underwent LSD with a new technique and present the advantages of less impairment during performance of this new technique.

METHODS

A cohort of 10 cirrhotic patients with bleeding portal hypertension and secondary hypersplenism treated with LSD were studied. During the procedure, an electromechanical morcellator allowed for easy extraction of the entire massive splenic tissue without a cumbersome intracorporeal bag, enlarged incision, or hand-assisted incision. Various perioperative data were recorded.

RESULTS

LSD was successful in all patients. There was no conversion to open operations or significant perioperative complications. The operative time was 288.0 ± 53.9 minutes, the spleen removal time was 39.3 ± 15.1 minutes, and blood loss was 240.0 ± 217.1 mL.

CONCLUSIONS

This new technique involving the use of an electromechanical morcellator provides expedient recovery and minimal postoperative pain and scarring. LSD with this technique is a feasible, effective, and safe surgical procedure, and embodies all the benefits of minimally invasive surgery for cirrhotic patients with bleeding portal hypertension and hypersplenism.

Для цитирования: Jiang Guoqing, Qian Jianjun, Yao Jie, Wang Xiaodong, Jin Shengjie, Bai Dousheng. A new technique for laparoscopic splenectomy and azygoportal disconnection.. Surgical innovation. 2013. DOI: 10.1177/1553350613492587.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.