JCI insight · 2026
Detection of cytokine release syndrome using wearables and cytokine profiling following CAR-T therapy for myeloma.
СтатьяНаблюдательное исследованиеПоддержка NIH: внешняя программаНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Rajeeve Sridevi, Wilkes Matt, Zahradka Nicole, Tomalin Lewis, Quidwai Mujahid, Pan Darren, Calafat Nicholas J, Cusack Martin, Aleman Adolfo, Serebryakova Kseniya, Kappes Katerina, Jackson Hayley, Agte Sarita, Thibaud Santiago, Sanchez Larysa, Richard Shambavi, Richter Joshua, Rodriguez Cesar, Cho Hearn Jay, Chari Ajai, Jagannath Sundar, Laganà Alessandro, Rossi Adriana C, Parekh Samir
Аннотация
BACKGROUNDChimeric antigen receptor T-cell (CAR-T) therapies have revolutionized treatment for relapsed/refractory multiple myeloma (RRMM). However, cytokine release syndrome (CRS), a common and potentially severe complication, requires inpatient monitoring, limiting access and increasing costs. Wearable devices could support outpatient CAR-T delivery, but feasibility for CRS detection versus standard care remains unproven.METHODSWe conducted a prospective, single-center observational pilot study to assess the feasibility of using wearable devices for monitoring vital signs and detecting CRS. Thirty patients receiving idecabtagene vicleucel (ide-cel) or ciltacabtagene autoleucel (cilta-cel) were enrolled; 25 with sufficient monitoring data were evaluable. Sensors collected skin and axillary temperature, oxygen saturation, respiratory and heart rate, and motion. Peripheral blood cytokines were analyzed pre- and postinfusion using a multiplex proteomic platform. The primary outcome was feasibility, assessed by CRS detection sensitivity and specificity; secondary outcomes included adherence, lead time, and performance of models integrating wearable and cytokine data.RESULTSCRS occurred in 20 of 25 patients. The best-performing wearable model detected 18 or 20 CRS episodes with a sensitivity of 0.72 (mean 0.75; 95% CI 0.60-0.91) and a specificity of 0.80 (mean 0.76; 95% CI 0.68-0.84), and a median lead time of 7:00 hours before nursing recognition. Median adherence during high-risk periods was 71%. Cytokine changes paralleled temperature elevations, and IFN-γ emerged as a consistent biomarker.CONCLUSIONWearable devices are feasible for early CRS detection and may support outpatient CAR-T care. Larger outpatient studies are warranted.TRIAL REGISTRATIONThis study did not meet the criteria for ClinicalTrials.gov registration.