MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1159/000540838

Медицинская библиотека · Blood purification · 2024

Relative Blood Volume Monitoring during Continuous Renal Replacement Therapy: A Prospective Observational Study.

Maeda Akinori, Baldwin Ian, Spano Sofia, Chaba Anis, Phongphithakchai Atthaphong, Pattamin Nuttapol, Hikasa Yukiko, Bellomo Rinaldo, See Emily

СтатьяНаблюдательное исследованиеПеревод в очереди

Аннотация

INTRODUCTION

Hematocrit monitoring during continuous renal replacement therapy (CRRT) allows the continuous estimation of relative blood volume (RBV). This may enable early detection of intravascular volume depletion prior to clinical sequelae. We aimed to investigate the feasibility of extended RBV monitoring and its epidemiology during usual CRRT management by clinicians unaware of RBV. Moreover, we studied the association between changes in RBV and net ultrafiltration (NUF) rates.

METHODS

In a cohort of adult intensive care unit patients receiving CRRT, we continuously monitored hematocrit and RBV using a pre-filter noninvasive optical sensor. We analyzed temporal changes in RBV and investigated the association between RBV change and NUF rates, using the classification of NUF rates into low, moderate, or high based on predefined cut-offs.

RESULTS

We obtained >60,000 minute-by-minute measurements in >1,000 CRRT hours in 36 patients. The median RBV change was negative (decrease) in 69% of patients and the median peak change in RBV was -9.3% (interquartile range: -3.9% to -14.3%). Moreover, the median RBV decreased from baseline by >5% in 40.2% of measurements and by >10% in 20.6% of measurements. Finally, RBV decreased significantly more when patients received a high NUF rate (>1.75 mL/kg/h) compared to low or moderate NUF rates (5.32% vs. 1.93% or 1.97%, p < 0.001).

CONCLUSION

Continuous hematocrit and RBV monitoring during CRRT was feasible. RBV decreased significantly during CRRT, and decreases were greater with higher NUF rates. RBV monitoring may help optimize NUF management and prevent the occurrence of intravascular volume depletion.

Для цитирования: Maeda Akinori, Baldwin Ian, Spano Sofia, Chaba Anis, Phongphithakchai Atthaphong, Pattamin Nuttapol, Hikasa Yukiko, Bellomo Rinaldo, See Emily. Relative Blood Volume Monitoring during Continuous Renal Replacement Therapy: A Prospective Observational Study.. Blood purification. 2024. DOI: 10.1159/000540838.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.