MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1038/s41467-020-20639-6

Медицинская библиотека · Nature communications · 2021

A glucose meter interface for point-of-care gene circuit-based diagnostics.

Amalfitano Evan, Karlikow Margot, Norouzi Masoud, Jaenes Katariina, Cicek Seray, Masum Fahim, Sadat Mousavi Peivand, Guo Yuxiu, Tang Laura, Sydor Andrew, Ma Duo, Pearson Joel D, Trcka Daniel, Pinette Mathieu, Ambagala Aruna, Babiuk Shawn, Pickering Bradley, Wrana Jeff, Bremner Rod, Mazzulli Tony, Sinton David, Brumell John H, Green Alexander A, Pardee Keith

СтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПоддержка правительства СШАПеревод в очереди

Аннотация

Recent advances in cell-free synthetic biology have given rise to gene circuit-based sensors with the potential to provide decentralized and low-cost molecular diagnostics. However, it remains a challenge to deliver this sensing capacity into the hands of users in a practical manner. Here, we leverage the glucose meter, one of the most widely available point-of-care sensing devices, to serve as a universal reader for these decentralized diagnostics. We describe a molecular translator that can convert the activation of conventional gene circuit-based sensors into a glucose output that can be read by off-the-shelf glucose meters. We show the development of new glucogenic reporter systems, multiplexed reporter outputs and detection of nucleic acid targets down to the low attomolar range. Using this glucose-meter interface, we demonstrate the detection of a small-molecule analyte; sample-to-result diagnostics for typhoid, paratyphoid A/B; and show the potential for pandemic response with nucleic acid sensors for SARS-CoV-2.

Для цитирования: Amalfitano Evan, Karlikow Margot, Norouzi Masoud, Jaenes Katariina, Cicek Seray, Masum Fahim, Sadat Mousavi Peivand, Guo Yuxiu, Tang Laura, Sydor Andrew, Ma Duo, Pearson Joel D, Trcka Daniel, Pinette Mathieu, Ambagala Aruna, Babiuk Shawn, Pickering Bradley, Wrana Jeff, Bremner Rod, Mazzulli Tony, Sinton David, Brumell John H, Green Alexander A, Pardee Keith. A glucose meter interface for point-of-care gene circuit-based diagnostics.. Nature communications. 2021. DOI: 10.1038/s41467-020-20639-6.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.