MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/pace.14068

Медицинская библиотека · Pacing and clinical electrophysiology : PACE · 2020

Dynamic voltage threshold adjusted substrate modification technique for complex atypical atrial flutters with varying circuits.

Methachittiphan Nilubon, Akoum Nazem, Gopinathannair Rakesh, Boyle Patrick M, Sridhar Arun R

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Atypical atrial flutter (AFL) is common in patients with postsurgical atrial scar, with macro- or microscopic channels in the scar acting as substrate for reentry. Heterogeneous atrial scarring can cause varying flutter circuits, which makes mapping and ablation challenging, and recurrences common.

AIM: We hypothesize that dynamically adjusting voltage thresholds can identify heterogeneous atrial scarring, which can then be effectively homogenized to eliminate atypical AFLs.

METHODS

We studied consecutive patients who presented to Electrophysiology laboratory for atypical AFL ablation with history of atriotomy and included the patients with multiple, varying flutter circuits during mapping in our study. We excluded patients with stable flutter circuit that was sustained and could be localized using traditional entrainment and activation mapping strategy. In the included patients, we performed detailed high-density voltage map of the atrium of interest. We adjusted voltage thresholds as needed to identify heterogeneity and channels in the scarred regions. A thorough scar homogenization was performed with irrigated smart-touch ablation catheter. Re-inducibility of tachycardia, and immediate and long-term outcomes were studied.

RESULTS

Of five studied cases, one was female; age 66 ± 10 years. All five had prior surgical substrate. All the patients had multiple flutter morphologies, which varied as we mapped the AFL. After scar homogenization, tachycardia was not inducible in any patient. No recurrence of flutter was noted during a mean follow-up duration of 450 ± 27 days.

CONCLUSION

High-density voltage mapping and homogenization of the scar can be an effective strategy in eliminating complex scar-mediated atypical AFL with multiple circuits.

Для цитирования: Methachittiphan Nilubon, Akoum Nazem, Gopinathannair Rakesh, Boyle Patrick M, Sridhar Arun R. Dynamic voltage threshold adjusted substrate modification technique for complex atypical atrial flutters with varying circuits.. Pacing and clinical electrophysiology : PACE. 2020. DOI: 10.1111/pace.14068.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.