MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.rpth.2023.102284

Медицинская библиотека · Research and practice in thrombosis and haemostasis · 2023

von Willebrand factor Ristocetin co-factor activity to von Willebrand factor antigen level ratio for diagnosis of acquired von Willebrand syndrome caused by aortic stenosis.

Okubo Noriyuki, Sugawara Shingo, Fujiwara Tohru, Sakatsume Ko, Doman Tsuyoshi, Yamashita Mihoko, Goto Kota, Tateishi Masaki, Suzuki Misako, Shirakawa Ryutaro, Eura Yuka, Kokame Koichi, Hayakawa Masaki, Matsumoto Masanori, Kawate Yasunori, Miura Mizuki, Takiguchi Hiroshi, Soga Yoshimitsu, Shirai Shinichi, Ando Kenji, Arai Yoshio, Nakayoshi Takaharu, Fukumoto Yoshihiro, Takahama Hiroyuki, Yasuda Satoshi, Tamura Toshihiro, Watanabe Shin, Kimura Takeshi, Yaoita Nobuhiro, Shimokawa Hiroaki, Saiki Yoshikatsu, Kaikita Koichi, Tsujita Kenichi, Yoshii Shinji, Nakase Hiroshi, Fujimaki Shin-Ichi, Horiuchi Hisanori

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Severe aortic stenosis (AS) causes acquired von Willebrand syndrome by the excessive shear stress-dependent cleavage of high molecular weight multimers of von Willebrand factor (VWF). While the current standard diagnostic method is so-called VWF multimer analysis that is western blotting under nonreducing conditions, it remains unclear whether a ratio of VWF Ristocetin co-factor activity (VWF:RCo) to VWF antigen levels (VWF:Ag) of <0.7, which can be measured with an automated coagulation analyzer in clinical laboratories and is used for the diagnosis of hereditary von Willebrand disease.

OBJECTIVES

To evaluated whether the VWF:RCo/VWF:Ag is useful for the diagnosis of AS-induced acquired von Willebrand syndrome.

METHODS

VWF:RCo and VWF:Ag were evaluated with the VWF large multimer index as a reference, which represents the percentage of a patient's VWF high molecular weight multimer ratio to that of standard plasma in the VWF multimer analysis.

RESULTS

We analyzed 382 patients with AS having transaortic valve maximal pressure gradients of >30 mmHg, 27 patients with peripheral artery disease, and 46 control patients free of cardiovascular disease with osteoarthritis, diabetes, and so on. We assumed a large multimer index of <80% as loss of VWF large multimers since 59.0% of patients with severe AS had the indices of <80%, while no control patients or patients with peripheral artery disease, except for 2 patients, exhibited the indices of <80%. The VWF:RCo/VWF:Ag ratios, measured using an automated blood coagulation analyzer, were correlated with the indices (rs = 0.470, P < .001). When the ratio of <0.7 was used as a cut-off point, the sensitivity and specificity to VWF large multimer indices of <80% were 0.437 and 0.826, respectively.

CONCLUSION

VWF:RCo/VWF:Ag ratios of <0.7 may indicate loss of VWF large multimers with high specificity, but low sensitivity. VWF:RCo/VWF:Ag ratios in patients with AS having a ratio of <0.7 may be useful for monitoring the loss of VWF large multimers during their clinical courses.

Для цитирования: Okubo Noriyuki, Sugawara Shingo, Fujiwara Tohru, Sakatsume Ko, Doman Tsuyoshi, Yamashita Mihoko, Goto Kota, Tateishi Masaki, Suzuki Misako, Shirakawa Ryutaro, Eura Yuka, Kokame Koichi, Hayakawa Masaki, Matsumoto Masanori, Kawate Yasunori, Miura Mizuki, Takiguchi Hiroshi, Soga Yoshimitsu, Shirai Shinichi, Ando Kenji, Arai Yoshio, Nakayoshi Takaharu, Fukumoto Yoshihiro, Takahama Hiroyuki, Yasuda Satoshi, Tamura Toshihiro, Watanabe Shin, Kimura Takeshi, Yaoita Nobuhiro, Shimokawa Hiroaki, Saiki Yoshikatsu, Kaikita Koichi, Tsujita Kenichi, Yoshii Shinji, Nakase Hiroshi, Fujimaki Shin-Ichi, Horiuchi Hisanori. von Willebrand factor Ristocetin co-factor activity to von Willebrand factor antigen level ratio for diagnosis of acquired von Willebrand syndrome caused by aortic stenosis.. Research and practice in thrombosis and haemostasis. 2023. DOI: 10.1016/j.rpth.2023.102284.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.