Multicenter comparison of the efficacy on prevention of pressure ulcer in postoperative patients between two types of pressure-relieving mattresses in China.
Аннотация
OBJECTIVE
Present study is designed to evaluate the effects of preventing pressure ulcer in surgical patients with two types of pressure-relieving mattresses.
METHODS
1074 surgical patients from 12 hospitals in China were divided into A group (static air mattress with repositioning every 2 hours, n = 562) and B group (power pressure air mattress with repositioning every 2 hours, n = 512). The patient was subjected to a pressure-relieving mattress and observed from 0-5 days after surgery. Indications include the Braden scores, hospital-acquired pressure ulcers (HAPU) incidence and stage.
RESULTS
The Braden scores between two groups in five days after surgery were no significant (P > 0.05). The incidence of HAPU between two groups in same days also was no significant (1.07% vs. 0.98%, P > 0.05). The incidence of Stage I and stage II pressure ulcers in group A and B were 1.07% (6/562) and 0.98% (5/512), respectively (χ(2) = 0.148, P = 0.882).
CONCLUSION
The effects of preventing pressure ulcer in surgical patients with two types of pressure-relieving mattresses are similar, but the protocol by static air mattress with repositioning every 2 hours is benefit when no power.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.