BACKGROUND

Postoperative Pancreatic Fistula (POPF) development remains a challenge after pancreaticoduodenectomy, occurring in 3-45% of cases [1]. The placement of a trans-anastomotic Wirsung stent is usually done in high-risk patients to decrease incidence and severity of POPF.

METHODS

Herein, we present a fully robotic pancreaticoduodenectomy with a biodegradable ductal stent interposition in a 47 y.o. female with a main duct IPMN of the pancreatic head and a fistula risk score of 6 (Moderate-risk).

VIDEO: After gastrocolic ligament division and hepatic flexure and duodenum mobilization, the loco-regional lymphadenectomy was performed. Following gastric transection with endo-GIA, the bile duct and gastroduodenal artery have been divided, and the cholecystectomy performed. The neck of the pancreas has been transected, the jejunum divided with endo-GIA and mobilized from the Treitz ligament, and the uncinate process dissected from the mesenteric vessels. A Blumgart anastomosis has been performed between the soft-texture pancreatic stump and the jejunal loop with the interposition of a 6 Fr/60 mm long, medium degrading stent (20 days) in the 2 mm duct (Archimedes BPS®, AMG Int., Winsen-Germany). The hepatico-jejunostomy and gastro-jejunostomy have been performed distally on the same loop. Three abdominal drains have been positioned.

RESULTS

Surgery lasted 480 min, with 175 mls blood loss. The patient postoperatively developed a biochemical leak and was discharged home by day 12. She was readmitted a month later for an amylase-negative intra-abdominal abscess that was successfully treated with percutaneous drainage.

CONCLUSION

Biodegradable pancreatic stent positioning could be an effective strategy in reducing POPF occurrence in high-risk patients.

Для цитирования: Troisi Roberto I, Alagia Mariantonietta, Nasto Riccardo A, Rompianesi Gianluca. Robotic pancreaticoduodenectomy with biodegradable ductal stenting (Archimedes BPS®).. Surgical oncology. 2022. DOI: 10.1016/j.suronc.2021.101706.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.