MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00256-021-03981-8

Медицинская библиотека · Skeletal radiology · 2022

Novel anterior coracoglenoid line utilizing magnetic resonance imaging (MRI) corresponds with critical glenoid bone loss.

Olmscheid Neil, Crawford Stanley D, Dickinson Christopher, Fajardo Ryan S, Knake Jeffrey J, Wilcox Christopher L, Joyner Patrick

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

Glenoid bone loss is estimated using a best-fit circle method and requires software tools that may not be available. Our hypothesis is that a vertical reference line drawn parallel to the long axis of the glenoid and passing through the inflection point of the coracoid and glenoid will represent a demarcation line of approximately 20% of the glenoid. Our aim is to establish a more efficient method to estimate a surgical threshold for glenoid insufficiency.

METHODS

Fifty patients with normal glenoid anatomy were randomly chosen from an orthopedic surgeon's database. Two orthopedic surgeons utilized T1-weighted sagittal MRIs and the coracoglenoid line technique to determine the percentage of bony glenoid anterior to vertical line. Two musculoskeletal radiologists measured the same 50 glenoids using the circle technique. Differences were determined using dependent t test. Reliability was compared using interclass correlation coefficient and Kappa. Validity was compared using Pearson correlation coefficient.

RESULTS

Mean surface area of the glenoid anterior to the vertical line was on average 21.69% ± 3.12%. Surface area of the glenoid using the circle method was on average 20.86% ± 2.29%. Inter-rater reliability of the circle method was 0.553 (fair). Inter-rater reliability of the vertical line technique was 0.83 (excellent). There was a linear relationship between circle and vertical line measurements, r = 0.704 (moderate to high).

CONCLUSION

The coracoglenoid line appears to represent a line of demarcation of approximately 21% of glenoid bone anterior to the coracoglenoid line. Our technique was found to be reliable, valid, and accurate.

Для цитирования: Olmscheid Neil, Crawford Stanley D, Dickinson Christopher, Fajardo Ryan S, Knake Jeffrey J, Wilcox Christopher L, Joyner Patrick. Novel anterior coracoglenoid line utilizing magnetic resonance imaging (MRI) corresponds with critical glenoid bone loss.. Skeletal radiology. 2022. DOI: 10.1007/s00256-021-03981-8.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.