Automated lung ultrasound image assessment using artificial intelligence to identify fluid overload in dialysis patients.

Tan Grace Feng Ling, Du Tiehua, Liu Justin Shuang, Chai Chung Cheen, Nyein Chan Maung, Liu Allen Yan Lun

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Fluid assessment is challenging, and fluid overload poses a significant problem among dialysis patients, with pulmonary oedema being the most serious consequence. Our study aims to develop a simple objective fluid assessment strategy using lung ultrasound (LUS) and artificial intelligence (AI) to assess the fluid status of dialysis patients.

METHODS

This was a single-centre study of 76 hemodialysis and peritoneal dialysis patients carried out between July 2020 to May 2022. The fluid status of dialysis patients was assessed via a simplified 8-point LUS method using a portable handheld ultrasound device (HHUSD), clinical examination and bioimpedance analysis (BIA). The primary outcome was the performance of 8-point LUS using a portable HHUSD in diagnosing fluid overload compared to physical examination and BIA. The secondary outcome was to develop and validate a novel AI software program to quantify B-line count and assess the fluid status of dialysis patients.

RESULTS

Our study showed a moderate correlation between LUS B-line count and fluid overload assessed by clinical examination (r = 0.475, p < 0.001) and BIA (r = 0.356. p < 0.001). The use of AI to detect B-lines on LUS in our study for dialysis patients was shown to have good agreement with LUS B lines observed by physicians; (r = 0.825, p < 0.001) for the training dataset and (r = 0.844, p < 0.001) for the validation dataset.

CONCLUSION

Our study confirms that 8-point LUS using HHUSD, with AI-based detection of B lines, can provide clinically useful information on the assessment of hydration status and diagnosis of fluid overload for dialysis patients in a user-friendly and time-efficient way.

Для цитирования: Tan Grace Feng Ling, Du Tiehua, Liu Justin Shuang, Chai Chung Cheen, Nyein Chan Maung, Liu Allen Yan Lun. Automated lung ultrasound image assessment using artificial intelligence to identify fluid overload in dialysis patients.. BMC nephrology. 2022. DOI: 10.1186/s12882-022-03044-7.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.