Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2025
Stent-assisted coiling using the pEGASUS-HPC stent for acutely ruptured wide-necked intracranial aneurysms: A multicenter retrospective study.
СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Aburub Abdallah, Ali Zakarya, Khanafer Ali, Moher Alsady Tawfik, Dob Oussama, Nimsky Christopher, Grote Alexander, Alhaj Mouatafa Bayan, Korthäuer Julia, Felber Stephan, Henkes Hans, Kemmling André, Almohammad Mohammad
Аннотация
BackgroundStent-assisted coiling (SAC) is increasingly used to treat ruptured wide-necked intracranial aneurysms. The pEGASUS-HPC stent, featuring a hydrophilic polymer coating (HPC) to reduce thrombogenicity, may offer a safe option in subarachnoid hemorrhage (SAH). This study evaluates its safety and efficacy in a multicenter retrospective cohort.MethodsBetween July 2021 and June 2024, 22 patients with ruptured wide-necked aneurysms were treated with pEGASUS-HPC SAC at four neurovascular centers. Procedural success, aneurysm occlusion (Modified Raymond-Roy Classification, MRRC), and clinical outcomes based on the modified Rankin Scale (mRS) at discharge and follow-up were assessed. Complications and mortality were analyzed in relation to clinical and procedural factors.ResultsStent implantation and coil embolization were successfully performed in all patients. Immediate complete occlusion (MRRC I) was achieved in 19 cases (86.4%) and reached 100% at the 3-month follow-up. The median mRS improved from 3 (2-5) at discharge to 0 (0-2) at 3 months and 0 (0-1) at final follow-up, indicating sustained recovery. In 27.3% of cases, Y-stenting was required, reflecting bifurcation complexity. One patient (4.6%) had transient in-stent thrombosis, which resolved with tirofiban. All complications were minor and managed conservatively. No retreatment was required. All three deaths (13.6%) occurred in patients with Hunt and Hess grade V and basilar artery aneurysms.ConclusionThe pEGASUS-HPC stent showed a favorable safety profile with high occlusion and recovery rates in ruptured wide-necked aneurysms. These findings support the use of surface-modified stents in the acute setting and highlight the need for prospective studies to confirm long-term safety and efficacy.