MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.hroo.2021.04.003

Медицинская библиотека · Heart rhythm O2 · 2021

Implantable loop recorder for augmenting detection of new-onset atrial fibrillation after typical atrial flutter ablation.

Peng Gary, Lin Aung N, Obeng-Gyimah Edmond, Hall Samantha N, Yang Ya-Wen, Chen Shiquan, Riley Michael, Deo Rajat, Ali Aasima, Arkles Jeffery, Epstein Andrew E, Dixit Sanjay

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Patients with typical atrial flutter (AFL) undergoing successful cavotricuspid isthmus ablation remain at risk for future development of new-onset atrial fibrillation (AF). Conventional monitoring (CM) techniques have shown AF incidence rates of 18%-50% in these patients.

OBJECTIVES

To evaluate whether continuous monitoring using implantable loop recorders (ILRs) would enhance AF detection in this patient population.

METHODS

Veteran patients undergoing AFL ablation between 2002 and 2019 who completed at least 6 months of follow-up after the ablation procedure were included. We compared new-onset AF detection between those who underwent CM and those who received ILRs immediately following AFL ablation.

RESULTS

A total of 217 patients (age: 66 ± 9 years; all male) participated. CM was used in 172 (79%) and ILR in 45 (21%) patients. Median follow-up duration after ablation was 4.1 years. Seventy-nine patients (36%) developed new-onset AF, which was detected by CM in 51 and ILR in 28 (30% vs 62%, respectively, P < .001). AF detection occurred at 7.7 months (IQR: 4.7-17.5) after AFL ablation in the ILR group vs 41 months (IQR: 23-72) in the CM group (P < .001). Eleven patients (5%) experienced cerebrovascular events (all in the CM group) and only 4 of these patients (36%) were on long-term anticoagulation.

CONCLUSION

Patients undergoing AFL ablation remain at an increased risk of developing new-onset AF, which is detected sooner and more frequently by ILR than by CM. Improving AF detection may allow optimization of rhythm management strategies and anticoagulation in this patient population.

Для цитирования: Peng Gary, Lin Aung N, Obeng-Gyimah Edmond, Hall Samantha N, Yang Ya-Wen, Chen Shiquan, Riley Michael, Deo Rajat, Ali Aasima, Arkles Jeffery, Epstein Andrew E, Dixit Sanjay. Implantable loop recorder for augmenting detection of new-onset atrial fibrillation after typical atrial flutter ablation.. Heart rhythm O2. 2021. DOI: 10.1016/j.hroo.2021.04.003.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.