DOI 10.1111/eci.13977

Медицинская библиотека · European journal of clinical investigation · 2023

Age differences of patients treated with wearable cardioverter defibrillator: Data from a multicentre registry.

El-Battrawy Ibrahim, Tenbrink David, Kovacs Boldizsar, Dreher Tobias C, Blockhaus Christian, Klein Norbert, Shin Dong-In, Hijazi Mido, Rosenkaimer Stephanie, Beiert Thomas, Abumayyaleh Mohammad, Saguner Ardan Muammer, Kowitz Jacqueline, Erath Julia W, Duru Firat, Mügge Andreas, Aweimer Assem, Akin Ibrahim

Многоцентровое исследованиеСтатьяПеревод в очереди

Аннотация

BACKGROUND

Wearable cardioverter defibrillators (WCD) are used as a 'bridging' technology in patients, who are temporarily at high risk for sudden cardiac death (SCD). Several factors should be taken into consideration, for example patient selection, compliance and optimal drug treatment, when WCD is prescribed. We aimed to present real-world data from seven centres from Germany and Switzerland according to age differences regarding the outcome, prognosis, WCD data and compliance.

MATERIALS AND

METHODS

Between 04/2012 and 03/2021, 1105 patients were included in this registry. Outcome data according to age differences (old ≥45 years compared to young <45 years) were analysed. At young age, WCDs were more often prescribed due to congenital heart disease and myocarditis. On the other hand, ischaemic cardiomyopathy (ICM) was more present in older patients. Wear days of WCD were similar between both groups (p = .115). In addition, during the WCD use, documented arrhythmic life-threatening events were comparable [sustained ventricular tachycardia: 5.8% vs. 7.7%, ventricular fibrillation (VF) .5% vs. .6%] and consequently the rate of appropriate shocks was similar between both groups. Left ventricular ejection fraction improvement was documented over follow-up with a better improvement in younger patients as compared to older patients (77% vs. 63%, p = .002). In addition, at baseline, the rate of atrial fibrillation was significantly higher in the older age group (23% vs. 8%; p = .001). The rate of permanent cardiac implantable electronic device implantation (CiED) was lower in the younger group (25% vs. 36%, p = .05). The compliance rate defined as wearing WCD at least 20 h per day was significantly lower in young patients compared to old patients (68.9% vs. 80.9%, p < .001). During the follow-up, no significant difference regarding all-cause mortality or arrhythmic death was documented in both groups. A low compliance rate of wearing WCD is predicted by young patients and patients suffering from non-ischaemic cardiomyopathies.

CONCLUSION

Although the compliance rate in different age groups is high, the average wear hours tended to be lower in young patients compared to older patients. The clinical events were similar in younger patients compared to older patients.

Для цитирования: El-Battrawy Ibrahim, Tenbrink David, Kovacs Boldizsar, Dreher Tobias C, Blockhaus Christian, Klein Norbert, Shin Dong-In, Hijazi Mido, Rosenkaimer Stephanie, Beiert Thomas, Abumayyaleh Mohammad, Saguner Ardan Muammer, Kowitz Jacqueline, Erath Julia W, Duru Firat, Mügge Andreas, Aweimer Assem, Akin Ibrahim. Age differences of patients treated with wearable cardioverter defibrillator: Data from a multicentre registry.. European journal of clinical investigation. 2023. DOI: 10.1111/eci.13977.