Duration of neuromuscular blockade following standard induction dose of rocuronium in parotid surgery: a retrospective observational study.

Higashino Masaaki, Kawata Ryo, Kikuoka Yusuke, Kinoshita Ichita, Jinnin Tsuyoshi, Tochizawa Takeshi, Terada Tetsuya, Haginomori Shin-Ichi

СтатьяНаблюдательное исследованиеПеревод в очереди

Аннотация

BACKGROUND

Due to the effects of NMBA administered during induction, intraoperative nerve monitoring may not respond properly during parotid gland surgery.

OBJECTIVE

To investigate the relationship between NMBA administration during anesthesia induction and the time to recovery for intraoperative nerve monitoring in parotid gland surgery.

MATERIALS AND

METHODS

We retrospectively reviewed the medical records of 190 patients who underwent surgery for benign parotid tumors. We examined the factors associated with prolonged neuromuscular blockade. The correlation between NMBA dose per body weight and time to TOFC = 4 was also examined.

RESULTS

The incidence of TOFC = 4 was 5.3% at 20 min, 33.2% at 40 min, 73.1% at 60 min, 91.6% at 80 min, and 96.3% at 100 min after NMBA administration. The time to TOFC = 4 was prolonged with a higher rocuronium dose per body weight, older age, and reduced renal function, each being an independent factor. A positive correlation was observed between NMBA dose and time to TOFC = 4. The administering rocuronium at 0.6 mg/kg during induction resulted in a TOFC = 4 time of 51.5 min.

CONCLUSION

In parotid gland surgery, the effects of NMBAs used during induction may persist in some cases.

Для цитирования: Higashino Masaaki, Kawata Ryo, Kikuoka Yusuke, Kinoshita Ichita, Jinnin Tsuyoshi, Tochizawa Takeshi, Terada Tetsuya, Haginomori Shin-Ichi. Duration of neuromuscular blockade following standard induction dose of rocuronium in parotid surgery: a retrospective observational study.. Acta oto-laryngologica. 2026. DOI: 10.1080/00016489.2026.2673945.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.