Endotypic Mechanisms of Successful Hypoglossal Nerve Stimulation for Obstructive Sleep Apnea.

Op de Beeck Sara, Wellman Andrew, Dieltjens Marijke, Strohl Kingman P, Willemen Marc, Van de Heyning Paul H, Verbraecken Johan A, Vanderveken Olivier M, Sands Scott A, STAR Trial Investigators

Сравнительное исследованиеСтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Rationale: Approximately one-third of patients with obstructive sleep apnea (OSA) treated with hypoglossal nerve stimulation (HGNS) therapy are incomplete responders, despite careful patient selection based on baseline characteristics and drug-induced sleep endoscopy.

Objectives

Here we use polysomnographic endotyping to assess the pathophysiological mechanisms underlying favorable versus incomplete responses to HGNS therapy.

Methods

Baseline polysomnography data of the STAR (Stimulation Therapy for Apnea Reduction) trial were included. Raw baseline polysomnographic data from 91/126 patients were available for analysis. Traits-loop gain, arousal threshold, collapsibility, and muscle compensation-were calculated from the baseline polysomnography data according to Sands and colleagues (AJRCCM 2018, SLEEP 2018). Logistic regression assessed apnea-hypopnea index (AHI)-adjusted associations between HGNS response (>50% reduction in AHI to <10/h at 1 yr) and OSA traits.Measurements and Main

Results

Overall, HGNS treatment reduced AHI from 30.7 (24.9-39.9) to 8.5 (4.0-19.5) events/h (P < 0.0001; median [quartiles 1-3]); N = 53/91 were responders. In adjusted analysis, a favorable response to therapy was independently associated with higher arousal threshold (odds ratio [95% confidence interval]: 6.76 [2.44-23.3], P = 0.001), greater compensation (odds ratio: 4.22 [1.70-12.55] per SD, P = 0.004), and lower loop gain (in milder collapsibility, per significant interaction, P = 0.003). The higher arousal threshold was evident in responders before adjusted analysis. Predicted responders had an approximately fourfold lower treatment AHI versus predicted nonresponders (4.9 [2.7-8.5] vs. 20.7 [10.9-29.7], P < 0.0001; median [quartiles 1-3]); differences remained significant after cross-validation.

Conclusions

Favorable responses to HGNS therapy are associated with the pathophysiological traits causing OSA, particularly a higher arousal threshold. Along with established criteria, individuals with favorable traits could potentially be prioritized for precision HGNS therapy.This analysis was a secondary analysis of the STAR trial registered with clinicaltrials.gov (NCT01161420).

Для цитирования: Op de Beeck Sara, Wellman Andrew, Dieltjens Marijke, Strohl Kingman P, Willemen Marc, Van de Heyning Paul H, Verbraecken Johan A, Vanderveken Olivier M, Sands Scott A, STAR Trial Investigators. Endotypic Mechanisms of Successful Hypoglossal Nerve Stimulation for Obstructive Sleep Apnea.. American journal of respiratory and critical care medicine. 2021. DOI: 10.1164/rccm.202006-2176oc.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.