m+Medelevator.RU
← Поиск публикаций
Journal of chromatography. B, Analytical technologies in the biomedical and life sciences · 2026

Liquid chromatography-tandem mass spectrometry-based urinary steroid profiling applied to primary aldosteronism diagnosis.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Zhong Jian, Ma Xiaoli, Wang Danchen, Luo Wei, Yin Yicong, Zou Yutong, Zhu Ying, Li Ming, Xie Shaowei, Yu Songlin, Qiu Ling

Аннотация

Steroid hormones are essential regulators of physiological homeostasis, which can help in diagnosing primary aldosteronism (PA). However, current methodologies for urinary steroid analysis face critical limitations, including narrow analyte coverage and tedious sample preparation workflows. Since the liquid chromatography-tandem mass spectrometry (LC-MS/MS) is considered the preferred technique for steroid measurement, there is a great need to establish an LC-MS/MS method combined with simplified and efficient sample pretreatment for multi-steroid profiling. We establish a novel LC-MS/MS method for quantifying 35 steroid hormones within a 25-min runtime. 40 μL of urine samples can be efficiently hydrolyzed at room temperature in just 0.5 h using transgenic β-glucuronidase. Detection is performed on the Waters Acquity I-Class UPLC-tandem with a Waters TQ-S triple quadrupole MS/MS system, and the method performance is systematically evaluated. Linearity is excellent, and the recovery rates range from 80.0 to 120.6%. Acceptable intra-assay and inter-assay precisions are achieved, with the coefficients of variation ranging from 1.86 to 15.10% and 3.91 to 19.75%, respectively. For clinical application, patients with PA (n = 37) exhibit significantly higher levels of aldosterone, tetrahydroaldosterone, 18-hydroxycorticosterone, 18-oxocortisol, and 18-hydroxycortisol compared to non-PA patients (n = 104). Combined steroid profiling demonstrates strong diagnostic performance for PA, yielding an area under the curve of 0.914, with a sensitivity of 0.87 and a specificity of 0.88. In conclusion, this study establishes a technically advanced LC-MS/MS method that integrates efficient enzymatic hydrolysis to enable the accurate quantification of urinary steroids for the diagnosis of endocrine disorders.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты