MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s12880-026-02781-7

Медицинская библиотека · BMC medical imaging · 2026

Weakly supervised anatomical feature learning for cross-dataset ejection fraction estimation from echocardiography videos.

Krenzer Adrian, Wieser Viktoria, Friedetzki Tobias

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Ejection fraction (EF) is a central measure of cardiac function, but echocardiographic EF assessment remains reader-dependent and sensitive to acquisition quality. Deep learning can automate EF estimation, yet performance measured on a single development dataset may not transfer to data acquired under different imaging and annotation conventions. We investigated whether anatomically constrained weakly supervised learning improves cross-dataset EF estimation.

METHODS

We propose CAFEx, a contrastive-augmented feature extraction pipeline that combines left ventricular segmentation, echocardiography-specific augmentation, mask-derived anatomical features, and temporal EF regression. The model was trained on EchoNet-Dynamic using video-level EF labels with limited dense annotations for the anatomical component. External evaluation was performed on CAMUS after image harmonization and recalculation of an apical-four-chamber monoplane EF endpoint. Performance was compared with reproduced segmentation-based, direct video-regression, graph-based, transformer-based, and feature-extraction baselines using Dice score, mean absolute error, and coefficient of determination.

RESULTS

In the harmonized train-on-EchoNet/test-on-CAMUS benchmark, anatomically constrained models degraded less than direct video-regression baselines. CAFEx achieved 90.73% Dice on CAMUS and improved CAMUS EF prediction over the strongest reproduced feature-extraction baseline, increasing [Formula: see text] from 0.38 to 0.54 and reducing mean absolute EF error from 7.89 to 6.70 percentage points. Poor-quality videos and extreme EF values remained challenging.

CONCLUSIONS

Weakly supervised EF estimation can benefit from an anatomical bottleneck learned with limited dense annotation. The findings support controlled external validation under explicit image and target harmonization, while further prospective validation, calibration, and quality-control mechanisms are needed before clinical deployment.

Для цитирования: Krenzer Adrian, Wieser Viktoria, Friedetzki Tobias. Weakly supervised anatomical feature learning for cross-dataset ejection fraction estimation from echocardiography videos.. BMC medical imaging. 2026. DOI: 10.1186/s12880-026-02781-7.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.