MedElevator Войти в исследования
← Поиск публикаций

DOI 10.12669/pjms.314.7538

Медицинская библиотека · Pakistan journal of medical sciences · 2015

Comparison of higher order aberrations in patients with various refractive errors.

Khan Muhammad Saim, Humayun Sadia, Fawad Aisha, Ishaq Mazhar, Arzoo Sabahat, Mashhadi Fawad

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

To compare the mean root mean square (RMS) of total higher order aberrations (HOAs), coma and spherical aberrations in individuals with myopia, hypermetropia and myopic astigmatism.

METHODS

This prospective analytical study was conducted at Armed Forces Institute of Ophthalmology, Rawalpindi, Pakistan from Jan 2014 to Dec 2014. Two hundred eyes of 121 patients with age ranging from 18-40 years were included in the study. Patients were divided into 4 group namely Low myopia, High myopia, Astigmatism and Hypermetropia on the basis of refractive error. Included were the patients who had refractive error more than ± 0.5D and best corrected visual acuity (BCVA) of 0.00 or better. Patients who had history of surgery and / or eye disease were excluded from the study. Visual acuity (VA), Spherical equivalent (SE) of refractive error, RMS value of total HOAs, coma and spherical aberrations were evaluated. HOAs were measured with aberrometer (Wavelight analyzer version 1073) at 6 mm pupil size.

RESULTS

Age of the patients ranged from 18 years to 40 years with mean age of 29.10±10.6 years. Seventy one (35.5%) were males and 129 (64.5%) were female. Mean RMS value of HOAs, coma and spherical aberrations was calculated in all four groups. RMS of total HOAs and spherical aberrations in hypermetropia was 0.96±0.96 and 0.30±0.42 respectively and it was higher than other three groups.

CONCLUSIONS

In overall comparison the mean RMS of total HOAs and spherical aberrations was significantly increased in hypermetropia group and there was a statistically significant negative correlation of SE of hypermetropia with RMS of total HOAs and spherical aberration.

Для цитирования: Khan Muhammad Saim, Humayun Sadia, Fawad Aisha, Ishaq Mazhar, Arzoo Sabahat, Mashhadi Fawad. Comparison of higher order aberrations in patients with various refractive errors.. Pakistan journal of medical sciences. 2015. DOI: 10.12669/pjms.314.7538.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.