Outcomes in Patients With Mitral Annular Disjunction and an Implantable-Cardioverter Defibrillator.
Аннотация
BACKGROUND
Mitral annular disjunction (MAD) carries an increased risk of complex ventricular arrhythmias, which can lead to sudden cardiac death. Many of these patients undergo implantable cardioverter defibrillator (ICD) implantation, but their ICD outcomes are not known.
OBJECTIVE
The aim of this study was to assess the outcomes of ICD implantation and the predictors of appropriate ICD therapies in patients with MAD.
METHODS
The study included patients with MAD who underwent ICD implantation. Clinical, electrocardiographic, cardiac imaging, and device therapy data were collected.
RESULTS
Forty-nine patients with MAD and ICD were included. Median age was 49 (21) years, and 29 (59%) were female. 13 (27%) patients underwent ICD implantation for primary prevention and 36 (73%) patients for secondary prevention. Over a median follow-up of 27.3 (35.3) months, 23 (47%) patients received ICD therapies. 18 (37%) patients had appropriate ICD therapies, and 5 (10%) patients had inappropriate ICD shocks. Median time to first appropriate therapy was 22.3 (63.3) months. In patients with a secondary prevention ICD indication, the rate of appropriate ICD therapies was 44%, while in patients with a primary prevention ICD indication, it was 15%. Among patients with appropriate ICD therapies, the first therapies were delivered for monomorphic ventricular tachycardia (VT) in 7 (39%) patients and polymorphic VT or ventricular fibrillation (VF) in 11 (61%) patients. Patients with appropriate ICD therapies were more likely to have a history of SCA (p = 0.003) and/or low left ventricular ejection fraction (LVEF) (p = 0.022) before ICD implantation as compared to patients without appropriate ICD therapies.
CONCLUSIONS
In our cohort of patients with MAD and ICD, appropriate ICD therapies were common. Most appropriate ICD therapies were delivered for polymorphic VT or VF. Larger studies are needed to elucidate the mechanisms of VAs and refine risk stratification in MAD.