MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1053/j.jvca.2026.07.033

Медицинская библиотека · Journal of cardiothoracic and vascular anesthesia · 2026

Hybrid 3D-Printed Manikin for Lung Isolation Training of Anesthesia Residents: A Randomized Controlled Trial.

Shaylor Ruth, Omer Itay, Haim Shimon, Rahman Evgeny, Eshel Ron, Goren Or, Cohen Barak

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

To evaluate if an anatomically accurate 3-dimensional (3D)-printed hybrid manikin improves procedural skill acquisition and retention for 1-lung ventilation (OLV) among anesthesia residents compared to a standard manikin.

DESIGN

Single-center, open-label randomized controlled trial.

SETTING

Tertiary university medical center.

PARTICIPANTS

Twenty-nine anesthesia residents with at least 1 month of experience (excluding those on thoracic rotations).

INTERVENTIONS: Following a 60-minute workshop, participants were randomized to train on either a standard airway trainer (control) or a hybrid model featuring a 3D-printed, anatomically realistic lower airway (study group).

MEASUREMENTS AND MAIN

RESULTS

Skills were assessed at baseline, post-workshop, and at 2 weeks, 2 months, and 6 months. The primary outcome was time to successful double-lumen tube (DLT) placement. Secondary outcomes included bronchoscopy global rating scores (GRS), bronchial blocker success, and time to identify the right upper lobe bronchus. Immediately postworkshop, the hybrid group was significantly faster at DLT placement (median 31 v 65 seconds; p = 0.002). At 2 months, the hybrid group maintained superior performance with higher DLT success rates (100% v 13%; p < 0.001) and better median GRS (12 v 10; p = 0.01). By 6 months, however, no significant differences remained between groups.

CONCLUSION

Training with a cost-effective, 3D-printed hybrid manikin enhances the acquisition and short-term durability of complex lung isolation skills. The convergence of scores by 6 months highlights significant procedural skill decay, emphasizing the need for regular refresher training.

Для цитирования: Shaylor Ruth, Omer Itay, Haim Shimon, Rahman Evgeny, Eshel Ron, Goren Or, Cohen Barak. Hybrid 3D-Printed Manikin for Lung Isolation Training of Anesthesia Residents: A Randomized Controlled Trial.. Journal of cardiothoracic and vascular anesthesia. 2026. DOI: 10.1053/j.jvca.2026.07.033.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.