MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00259-026-08014-x

Медицинская библиотека · European journal of nuclear medicine and molecular imaging · 2026

Are liver metastases from uveal melanoma a clinical indication for dynamic PET? A comparison of Patlak parametric imaging with standard and delayed static SUV imaging using long axial field-of-view PET/CT.

Pan Leyun, Sachpekidis Christos, Strauss Dimitrios S, Hassel Jessica C, Dimitrakopoulou-Strauss Antonia

СтатьяСравнительное исследованиеПеревод в очереди

Аннотация

PURPOSE: Despite decades of technical development, dynamic PET and parametric imaging have not yet achieved widespread clinical implementation in oncology, largely due to technical complexity and the limited number of clinical scenarios in which clear additional value over static imaging has been demonstrated. We hypothesized that liver metastases from uveal melanoma-a tumor entity often characterized by low tumor-to-background contrast on static imaging- may represent a particularly promising application for dynamic PET imaging. Accordingly, we aimed to determine whether dynamic Patlak parametric imaging improves lesion detectability and conspicuity compared with standard (50-60 min) and delayed (70-85 min) static standardized uptake value (SUV) imaging.

MATERIAL AND

METHODS

Twenty-six patients with uveal melanoma and a total of 126 tumor lesions, including 58 liver metastases and 68 other metastases, were prospectively enrolled. All patients underwent a 60 min dynamic data acquisition (skull to upper thigh) followed by whole-body [18F]FDG PET/CT imaging at 70 min post-injection. Three image datasets were generated and compared: (1) Direct Patlak Ki parametric images derived from dynamic acquisition at 30-60 min post-injection, (2) standard static SUV images reconstructed from same dynamic acquisition at 50-60 min post-injection (standardSUV), and (3) delayed static SUV images acquired at 70-85 min post-injection (lateSUV). All three image sets were assessed qualitatively for lesion detectability and quantitative analysis was performed for all 126 lesions using tumor-to-background ratio (TBRmean) measurements.

RESULTS

No significant differences were observed among the three imaging approaches with respect to the total number of detected tumor lesions. However, one discordant finding was noted: a true-positive liver metastasis was identified on Patlak Ki imaging and subsequently confirmed by MRI, but was not clearly visualized on static SUV images. Qualitatively, for liver and other metastases, Patlak Ki and lateSUV images showed significantly higher TBRmean values than standardSUV, with mean increases of ~ 2.1-2.3-fold for Ki and ~ 1.3-fold for lateSUV. Furthermore, Patlak Ki yielded significantly higher TBRmean than lateSUV (52/58 and 65/68) and standardSUV (57/58 and 67/68) for liver and other metastases, respectively.

CONCLUSIONS

Although lesion detection rates were not significantly increased, dynamic acquisition with Patlak parametric imaging provided a robust and less timing-dependent method to enhance tumor-to-background contrast compared with static SUV imaging and may yield discordant findings with additional clinical value in selected cases. Overall, Patlak imaging may therefore represent a complementary contrast-optimization approach for evaluating liver metastases from uveal melanoma.

Для цитирования: Pan Leyun, Sachpekidis Christos, Strauss Dimitrios S, Hassel Jessica C, Dimitrakopoulou-Strauss Antonia. Are liver metastases from uveal melanoma a clinical indication for dynamic PET? A comparison of Patlak parametric imaging with standard and delayed static SUV imaging using long axial field-of-view PET/CT.. European journal of nuclear medicine and molecular imaging. 2026. DOI: 10.1007/s00259-026-08014-x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.