MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3389/fmicb.2026.1898324

Медицинская библиотека · Frontiers in microbiology · 2026

Plasma kynurenine/tryptophan ratio as a sensitive blood-based diagnostic tool for tuberculosis: a diagnostic accuracy study among children living with HIV.

Adu-Gyamfi Clement G, Makhathini Lillian, Longlax Santiago C, Varela Alexandra Portillo, Scheuermaier Karine, Sikhondze Ntsiki, Otwombe Kennedy, Adjei Andrew Anthony, Martinson Neil, Kay Alex, DiNardo Andrew R, Mandalakas Anna M, Suchard Melinda

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Pediatric tuberculosis (TB) is challenging to diagnose and confirm. The World Health Organization has prioritized development of non-sputum-based diagnostics. We investigated the role of plasma K/T ratio for TB diagnosis among children with and without HIV.

METHODOLOGY: Plasma tryptophan and kynurenine concentrations measured via enzyme-linked immunosorbent assay (ELISA) were used to calculate K/T ratios in a nested case-control design with an optimization cohort (the Lung Cohort Study (LCS)) and a validation cohort (the NIH Stool4TB. The discovery cohort included children with incident TB (n = 23) and age- and sex-matched controls (n = 75). The Stool4TB validation cohort included participants with and without HIV who had microbiologically confirmed TB (n = 15) or clinically diagnosed TB (n = 20), and controls (n = 25).

RESULTS

LCS participants with HIV-associated TB had higher plasma K/T ratio (median 0.511 [IQR 0.182-0.820]) than controls (median 0.053 [IQR 0.030-0.072]), p < 0.0001. Among participants with microbiologically confirmed TB living with HIV, plasma K/T ratio gave a sensitivity of 95% (CI 79-99), specificity of 85% (CI 0.75-0.91), PPV of 85%, NPV of 98%, and AUC of 0.96 (95% CI 0.93-0.99). In the validation cohort, among HIV uninfected children, applying a cut-off value of 0.090 gave a sensitivity of 83 % (CI 0.43-0.99), specificity of 96% (CI 0.80-0.99), PPV of 96%, NPV of 90%, and AUC of 0.92 (95% CI 0.82-1) for laboratory confirmed TB. In the LCS, participants who had received intermittent preventative therapy had lower K/T ratio compared to those who did not (p = 0.0191).

CONCLUSION

Plasma K/T ratio is a sensitive non-sputum-based test for diagnosing TB in children and has promising application within pediatric TB diagnostic algorithms.

Для цитирования: Adu-Gyamfi Clement G, Makhathini Lillian, Longlax Santiago C, Varela Alexandra Portillo, Scheuermaier Karine, Sikhondze Ntsiki, Otwombe Kennedy, Adjei Andrew Anthony, Martinson Neil, Kay Alex, DiNardo Andrew R, Mandalakas Anna M, Suchard Melinda. Plasma kynurenine/tryptophan ratio as a sensitive blood-based diagnostic tool for tuberculosis: a diagnostic accuracy study among children living with HIV.. Frontiers in microbiology. 2026. DOI: 10.3389/fmicb.2026.1898324.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.