m+Medelevator.RU
Открытая медицинская библиотека

Литература по диагнозу
T84.2 · Ослож. мех. происхождения,связ. с внутр. устройством,фикс-им др. кости

Медицинские публикации, первоисточники и полные тексты.
Для клинического вопроса, нового знания и следующего исследования.

Доступно в поиске

165 публикаций

Поиск: 14 мс
Публикации на разных языках · PubMed, Europe PMC и данные издателей через Crossref · 0 с найденным полным текстом

Usefulness of the obturator hook technique for guiding the initial trajectory control in infra-acetabular screw placement.

PURPOSE: Proper placement of infra-acetabular screws is technically demanding; there is a limited safe zone for screw fixation because of the complexity of the bone anatomy around the hip joint and the vulnerability of the major neurovascular bundles in the pelvic cavity. We aimed to present the obturator hook technique as a surgical technique for infra-acetabular screw placement in acetabular and pelvic fractures and report its radiological outcomes. METHODS: Patients treated with infra-acetabular screw placement using the obturator hook technique between January 2015 and August 2020 were en

СтатьяПоддержка исследования: вне правительства СШАПолный текст не найденПеревод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

PMID 33641537Открыть статью

[Minimally invasive lumbopelvic stabilization of sacral fracture and sacroiliac injury].

OBJECTIVE: Rapid mobilization with full weight bearing by minimally invasive fixation of Os ilium to L5 in fractures of the sacrum and disruption of the sacroiliac joint (SIJ). INDICATIONS: Unstable injuries of the posterior pelvic ring in fractures of the sacrum and disruption of the SIJ. CONTRAINDICATIONS: Fracture of ilium and not injury related implants in the screw trajectory, neurological deficits regarding the fracture, decubitus in the area of surgical approach. SURGICAL TECHNIQUE: Minimally invasive screw placement in the pedicles of L5, access of ilium screw via the posterior supe

СтатьяОбзорПоиск полного текста в очередиПеревод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

PMID 34468791Открыть статью

Single lag screw and reverse distal femur locking compression plate for concurrent cervicotrochanteric and shaft fractures of the femur: biomechanical study validated with a clinical series.

BACKGROUND: The optimal surgical management of concurrent cervicotrochanteric and shaft fractures of the femur has not been consensual. The authors investigated the reliability of combined single lag screw and reverse distal femur locking compression plate (LCP-DF) by finite element (FE) study and retrospectively described the present technique for these dual fractures. METHOD: Intact femurs were derived from CT data, and the implant models were created by using CAD software. The fractured femur and implant models were virtually aligned based on the surgical techniques before converting to th

СтатьяПолный текст не найденПеревод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

PMID 33417049Открыть статью

An experimental study on stress-shielding effects of locked compression plates in fixing intact dog femur.

Источник пометил публикацию как отозванную

BACKGROUND: In orthopedic application, stress-shielding effects of implant materials cause bone loss, which often induces porosis, delayed bone healing, and other complications. We aimed to compare the stress-shielding effects of locked compression plate (LCP) and limited-contact dynamic compression plate (LC-DCP) in dogs with plate-fixed femurs. METHODS: Bilateral intact femurs of 24 adult dogs were fixed by adult forearm 9-hole titanium plates using minimally invasive plate osteosynthesis (MIPPO) technology, with LCP on the left and LC-DCP on the right femurs. Dogs were sacrificed at 6 week

Сравнительное исследованиеСтатьяОтозванная публикацияПолный текст не найденПеревод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

PMID 33514429Открыть статью

External fixator combined with three different fixation methods of fibula for treatment of extra-articular open fractures of distal tibia and fibula: a retrospective study.

BACKGROUND: To compare the efficacy of three different fixation methods of fibula combined with external fixation of tibia for the treatment of extra-articular open fractures of distal tibia and fibula. METHODS: From January 2017 to July 2019, 91 cases of open fractures of distal tibia and fibula were treated with external fixator, and the fibula was fixed with non-fixation (group A, n = 35), plate-screw (group B, n = 30) and Kirschner wire (group C, n = 26). The operation time, intraoperative blood loss, surgical and implants costs, fracture healing time, postoperative complications, and Ame

СтатьяПоиск полного текста в очередиПеревод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

PMID 33397351Открыть статью

Osteoperiosteal Decortication and Autogenous Cancellous Bone Graft Combined with Bridge Plating for Non-hypertrophic Diaphyseal Nonunion.

BACKGROUD: The aim of this study was to evaluate results of osteoperiosteal decortication and autogenous cancellous bone graft combined with a bridge plating technique in atrophic and oligotrophic femoral and tibial diaphyseal nonunion. METHODS: We retrospectively reviewed 31 patients with atrophic or oligotrophic femoral and tibial diaphyseal nonunion treated with osteoperiosteal decortication and autogenous cancellous bone graft between January 2008 and December 2018. Patients with hypertrophic nonunion, infected nonunion, and nonunion treated with autogenous cancellous bone graft alone wer

СтатьяПоиск полного текста в очередиПеревод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

PMID 34484621Открыть статью

Fibula fixation in the treatment of tibial pilon fractures - Is it really necessary?

BACKGROUND: There is a lack of consensus about the role of fibula fixation in these complex fractures, with only two clinical studies in the literature. We hypothesize that the fibula fracture need not be fixed in the tibial pilon fractures if primary stability can be achieved with tibial fixation alone. METHODS: We reviewed 79 patients with operatively treated tibial pilon with associated fibula fractures from 2007 to 2017 and divided them into two groups; patients with fibula fracture fixation and those without fixation. The primary outcome measure was any mechanical complications. Secondar

СтатьяПолный текст не найденПеревод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

PMID 34953685Открыть статью

Surgical challenges in posterior cervicothoracic junction instrumentation.

The cervicothoracic junction (CTJ) is a region of the spine submitted to significant mechanical stress. The peculiar anatomical and biomechanical characteristics make posterior surgical stabilization of this area particularly challenging. We present and discuss our surgical series highlighting the specific surgical challenges provided by this region of the spine. We have analyzed and reported retrospective data from patients who underwent a posterior cervicothoracic instrumentation between 2011 and 2019 at the Neurosurgical Department of the Geneva University Hospitals. We have discussed C7 an

СтатьяПоиск полного текста в очередиПеревод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

PMID 33754193Открыть статью

Impact of Screw Diameter on Pedicle Screw Fatigue Strength-A Biomechanical Evaluation.

OBJECTIVE: Loosening of pedicle screws is a frequently observed complication in spinal surgery. Because additional stabilization procedures such as cement augmentation or lengthening of the instrumentation involve relevant risks, optimal stability of the primarily implanted pedicle screw is of essential importance. The aim of the present study was to investigate the effect of increasing the screw diameter on pedicle screw stability. METHODS: A total of 10 human cadaveric vertebral bodies (L4) were included in the present study. The bone mineral density was evaluated using quantitative compute

СтатьяПолный текст не найденПеревод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

PMID 34087457Открыть статью

Hybrid screw fixation for femoral neck fractures: Does it prevent mechanical failure?

INTRODUCTION: Traditionally, femoral neck fracture fixation has been performed using three partially threaded cancellous screws. However, fracture collapse with femoral neck shortening, and varus deformation frequently occurs due to posterior medial comminution and lack of calcar support. We hypothesize replacing the inferior neck/calcar screw with a fully threaded, length stable, screw will provide improved biomechanical stability, decrease femoral neck shortening and varus collapse. METHODS: Ten matched cadaveric pairs (20 femurs) were randomly assigned to two screw fixation groups. Group 1

СтатьяРандомизированное исследованиеПолный текст не найденПеревод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

PMID 35676163Открыть статью

Pelvic incidence is a risk factor for lower instrumented vertebra failure in adult spinal deformity patients who underwent corrective fusion terminating at the L5 vertebra.

BACKGROUND: Factors related to postoperative mechanical failure after long fusion with lower instrumented vertebra (LIV) at L5 have not been well investigated. Elucidating such factors may allow us to perform alternatives to spinopelvic fusion for adult spinal deformity (ASD) cases. We investigated the incidence and risk factors of LIV failure in patients with ASD who underwent surgical treatment of long corrective fusion until the L5 vertebrae. METHODS: Between 2009 and 2018, 52 patients who underwent corrective fusions to L5 were followed-up for at least one-year. We evaluated the associate

СтатьяПолный текст не найденПеревод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

PMID 34924249Открыть статью

Biomechanical comparison of a 3.5 mm anterior locking plate to cannulated screws with anterior tension band wiring in comminuted patellar fractures.

PURPOSE: To date, surgically treated multifragmentary patellar fractures are still associated with high rates of complications, such as i.e. secondary fracture displacement. Osteosynthesis is most frequently performed with screws and cerclages. To increase primary stability, locking plates have been introduced. However, there is still a lack of biomechanical data supporting the superiority of plate fixation compared to screw fixation with cerclages in these cases. The goal of the present study was to conduct biomechanical comparison of these two techniques under dynamic loading conditions. ME

СтатьяПолный текст не найденПеревод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

PMID 32197829Открыть статью

[Clinical application of Taylor spatial frame in adjustment of lower extremity force line of knee medial compartmental osteoarthritis].

OBJECTIVE: To explore the safety and effectiveness of Taylor spatial frame (TSF) in the treatment of medial compartmental osteoarthritis (MCOA) of the knee and the adjustment of the lower extremity force line at the same time. METHODS: The clinical data of 30 patients with MCOA who underwent high tibial osteotomy (HTO) between October 2016 and April 2017 were retrospectively analyzed. According to the different fixation methods, they were divided into external fixation group (TSF external fixation, 16 cases) and internal fixation group (locking steel plate internal fixation, 14 cases). There

Сравнительное исследованиеСтатьяПолный текст не найденПеревод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

PMID 32291980Открыть статью

Ideal sagittal profile restoration and ideal lumbar apex positioning play an important role in postoperative mechanical complications after a lumbar PSO.

STUDY DESIGN: Retrospective analysis of prospectively collected data. OBJECTIVE: To determine the influence of postoperative ideal lordosis distribution and ideal sagittal harmony on mechanical complications in patients undergoing one-level lumbar pedicle subtraction osteotomy (L-PSO). Many variables have been associated with mechanical complications after L-PSO. However, the impact of restoring the ideal inflexion point, lumbar apex, and sagittal shape is still underexplored. METHODS: Analyzed risk factors were: age and patient-related variables, PSO level, interbody cages, rod material/dia

СтатьяПоддержка исследования: вне правительства СШАПоиск полного текста в очередиПеревод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

PMID 31925761Открыть статью

"Patient-specific" rods in the management of adult spinal deformity. One-year radiographic results of a prospective study about 86 patients.

INTRODUCTION: Based on global knowledge regarding sagittal alignment, preoperative planning is a crucial point in the management of adult spinal deformity (ASD). Patient-specific rods (PSR) have been recently developed in order to change preoperative planning into a postoperative reality. The aim of this study was therefore to analyze the 1-year radiographic results of prospective ASD cohorts managed using PSR. METHODS: In this prospective study, all patients managed for an ASD using PSR since 2014 and with a minimal follow-up of 1-year were included. Radiographic parameters were evaluated pr

СтатьяПоиск полного текста в очередиПеревод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

PMID 32360224Открыть статью

Comparison of effects of four interbody fusion approaches on the fused and adjacent segments under vibration.

BACKGROUND: Which lumbar fusion approaches having fewer impacts on the lumbar spine, reducing the risk of complications and the most conducive to bone fusion under whole-body vibration is urgent to know. OBJECTIVES: This study researched the best approach under vibration by comparing the effects of four different approaches on the spine, especially regarding some significant indexes related to complications and outcomes. METHODS: The L1-L5 finite element model was modified to simulate anterior, posterior, trans-foraminal and direct lateral lumbar interbody fusion approaches with bilateral pe

СтатьяПоддержка исследования: вне правительства СШАПоиск полного текста в очередиПеревод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

PMID 32417603Открыть статью

Safety Profile of Lumbosacropelvic Fixation in Patients Aged 60 Years or Older: Comparison Between S2-Alar-Iliac Screws and Conventional Iliac Screws.

STUDY DESIGN: This is a retrospective study. OBJECTIVE: To report the safety profile of S2-alar-iliac (S2AI) in patients over 60, comparing S2AI screws with iliac screws (ISs). SUMMARY OF BACKGROUND DATA: The surgical management involving the lumbosacropelvic spine remains a challenge due to high mechanical demand and risk of pseudarthrosis. Previous articles showed lower rates of complications in patients receiving S2AI screws than ISs; however, none of them have focused on patients aged over 60 who may harbor significant comorbidities and thus require more meticulous perioperative manageme

Сравнительное исследованиеСтатьяПолный текст не найденПеревод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

PMID 30789493Открыть статью

Treatment of distal femur fractures with VA-LCP condylar plate: A single trauma centre experience.

INTRODUCTION: Given the recent criticisms in the literature regarding Synthes Variable Angle Locking Compression Condylar Plate (VA-LCP), the purpose of this study was to evaluate functional outcome, fracture healing, and complications of distal femoral intra-articular fractures using this device. METHODS: Patients with distal femoral fractures treated with 4.5 mm VA-LCP Curved Condylar Plate were included in this retrospective study. Follow-ups were at 4 weeks, 3 months, 6 months and 1 year. For the clinical and functional assessment of the knee, WOMAC, Koos Knee Survey, the Knee Score Socie

СтатьяПолный текст не найденПеревод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

PMID 31703959Открыть статью

Evaluation of labial versus labio-inferior lines of osteosynthesis using 3D miniplate for fractures of anterior mandible: A finite element analysis with a pilot clinical trial.

PURPOSE: The fractures of anterior mandible are subject to severe torsional forces due to muscles acting in opposite directions. 3D miniplate has been suggested as a good alternative by some researchers. However, finite element model (FEM) studies indicate that labio-inferior positioning of two miniplates perpendicular to each other offers better stability as compared to labial positioning. This study aims at combining the advantages of a single 3D miniplate and labio-inferior positioning of two conventional miniplates, which was assessed by finite element analysis along with a pilot clinical

СтатьяПолный текст не найденПеревод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

PMID 31493976Открыть статью

Risk factor analysis for delayed union after subtrochanteric femur fracture: quality of reduction and valgization are the key to success.

BACKGROUND: Subtrochanteric femur fractures (SFF) are uncommon, but have a high complication rate concerning non-union and mechanical complications. There is ongoing discussion about risk factors for delayed fracture healing after SFF. The purpose of this study was to evaluate potential risk factors for delayed fracture healing after SFF. METHODS: This retrospective radio-morphometric case control study compares 61 patients after SFF in two groups (uncomplicated healing within 6 months postoperatively vs. delayed union) concerning radiographical properties. The patients were analyzed concerni

СтатьяПолный текст не найденПеревод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

PMID 31470831Открыть статью