Публикации на разных языках · PubMed, Europe PMC и данные издателей через Crossref · 108 с найденным полным текстом
The journal of maternal-fetal & neonatal medicine : the official journal of the European Association of Perinatal Medicine, the Federation of Asia and Oceania Perinatal Societies, the International Society of Perinatal Obstetricians2006eng
We performed uterine artery Doppler velocimetry in 16 nulliparous and 16 parous women with non-preeclamptic singleton gestations and 16 nulliparous and 16 parous women with dichorionic twin gestations at 17-18 and 26-27 weeks of gestation. In both singleton and twin pregnancies, the average pulsatility index (PI) in nulliparous women was significantly higher than that in parous women at 17-18 weeks of gestation. At 26-27 weeks of gestation, however, there were no significant differences in PI between nulliparous and parous women with either singleton or twin pregnancies. During the early secon
СтатьяПолный текст не найденПеревод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Before surgery we studied the blood flow in and around 59 breast tumours (35 malignant and 24 benign) and investigated a correlation with the histology. The most decisive factors were the maximum end-diastolic frequency B (probability greater than magnitude of z = 0.0009) and the mean frequency F mean (probability greater than magnitude of z = 0.0017). The maximum systolic frequency A, the resistance index Ri, the diastolic angle W and the pulsatility index Pi showed less significant differences between malignant and benign histological types. In a retrospective survey, we tried to confirm the
СтатьяПолный текст не найденПеревод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
BACKGROUND: Chronic left-to-right shunting, as occurs with congenital heart disease or persistent ductus-like flow, exposes pulmonary circulation to sustained high-flow shear and pulsatile pressure and causes severe, flow-mediated arteriopathy. A scalable, minimally invasive mouse model that reproduces this hemodynamic trigger is needed to enable mechanistic dissection in a genetically tractable system.
METHODS: An ultrasound-guided transcatheter aortopulmonary shunt procedure was developed to create ductus-like communication between the aortic arch and pulmonary artery. Shunt formation and p
СтатьяПолный текст не найденПеревод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
OBJECTIVES: Intimal tears caused by aortic dissection can weaken the arterial wall and lead to aortic aneurysms. However, the effect of different tear states on the blood flow behaviour remains complex. This study uses a novel approach that combines numerical haemodynamic simulation with in vitro experiments to elucidate the effect of arterial dissection rupture on the complex blood flow state within the abdominal aneurysm and the endogenous causes of end-organ malperfusion.
MATERIALS AND METHODS: Based on the CT imaging data and clinical physiological parameters, the overall arterial models
СтатьяПоддержка исследования: вне правительства СШАПоиск полного текста в очередиПеревод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Introduction: Direct quantification of hemodynamic factors applied to a cerebral aneurysm (CA) remains inaccessible due to the lack of technologies to measure the flow field within an aneurysm precisely. This study aimed to develop an in vitro validated 3D in silico patient-specific internal carotid artery sidewall aneurysm (ICASA) model which can be used to investigate hemodynamic factors on the CA pathophysiology. Methods: The validated ICASA model was developed by quantifying and comparing the flow field using particle image velocimetry (PIV) measurements and computational fluid dynamics (C
СтатьяПолный текст не найденПеревод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
UNLABELLED: Non-invasive measurement of cerebral blood flow (CBF) in humans is fraught with technologic, anatomic, and accessibility issues, which has hindered multi-vessel hemodynamic analysis of the cranial vasculature. Recent developments in cardiovascular MRI have allowed for the measurement of cine velocity vector fields over large imaging volumes in a single acquisition with 4D flow MRI. The purpose of this study was to develop an imaging protocol to simultaneously measure pulsatile flow in the circle of Willis as well as the carotid and vertebrate arteries at rest and during increased C…
СтатьяПоддержка исследования: вне правительства СШАПоиск полного текста в очередиПеревод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
OBJECTIVES: To investigate the imaging features of unilateral pulsatile tinnitus (PT) with jugular bulb wall dehiscence (JBWD).
METHODS: Computerized tomography angiography images of unilateral PT patients were reviewed between 2019 and 2021. Thirty-one symptomatic JBWD patients without sigmoid sinus wall dehiscence (SSWD) were included. Thirty-eight patients with SSWD were used as the control group. The prevalence of JBWD was calculated. The area and height of the jugular bulb, the extent of dehiscence, the presence of jugular bulb diverticulum, posterior condylar emissary vein (PCEV), obliq
СтатьяПоиск полного текста в очередиПеревод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
OBJECTIVE: Cerebral small vessel diseases (cSVDs) are a major cause of stroke and dementia. We used cutting-edge 7T-MRI techniques in patients with Cerebral Autosomal Dominant Arteriopathy with Subcortical Infarcts and Leukoencephalopathy (CADASIL), to establish which aspects of cerebral small vessel function are affected by this monogenic form of cSVD.
METHODS: We recruited 23 CADASIL patients (age 51.1 ± 10.1 years, 52% women) and 13 age- and sex-matched controls (46.1 ± 12.6, 46% women). Small vessel function measures included: basal ganglia and centrum semiovale perforating artery blood f
СтатьяПоддержка исследования: вне правительства СШАПоиск полного текста в очередиПеревод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Pre-eclampsia is associated with significant maternal and fetal morbidity and mortality worldwide. Pregnancy complicated by preeclampsia and/or by fetal growth restriction are reported to have inadequate maternal vascular responses to placentation. This defective vascular response was due to the failure of second wave of endovascular trophoblast migration leading to both a reduced amount and depth of trophoblast invasion of myometrium followed by the development of placental hypoxia and ischemia that can be measured biophysically by means of Doppler Ultrasound. The role of Doppler in the scree
СтатьяПолный текст не найденПеревод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
BACKGROUND: Impaired reactivity of cerebral blood vessels is associated with increased risk of stroke. Female sex hormones have vasoactive effects in a number of vascular beds but their effects upon the cerebral circulation are not well understood. Ultrasound techniques allow us to examine the ability of intracranial vessels to dilate in response to a pharmacological stimulus (the carbonic anhydrase inhibitor acetazolamide). We studied intracranial hemodynamics in a group of premenopausal women before and after induction of a temporary hypoestrogenic state.
METHODS: We examined middle cerebra
Контролируемое клиническое исследованиеСтатьяПоддержка исследования: вне правительства СШАПоиск полного текста в очередиПеревод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
OBJECTIVE: To explore the micro blood flow characteristics of normal singleton pregnancy placenta in middle and late pregnancy based on microvascular flow (MV-Flow) imaging.
METHODS: We conducted a retrospective cohort study. Clinical records and placental ultrasound images of 485 patients in mid to late pregnancy with normal fetal development who underwent MV-Flow microvascular imaging in The First Affiliated Hospital of Anhui Medical University from January 2023 to December 2023 were retrospectively analyzed. The gestational age of patients ranged from 22 to 38 weeks, and the biological mea
СтатьяПолный текст не найденПеревод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
OBJECTIVE: To compare umbilical vein (UV) flow with standard Doppler parameters in prediction of adverse perinatal outcome in late-onset small-for-gestational age (SGA) fetuses.
METHODS: Umbilical, uterine and middle cerebral arteries, and UV blood flow were evaluated by Doppler before delivery in a cohort of 193 term SGA fetuses. The value of the Doppler parameters to predict risk of emergency delivery for non-reassuring fetal status and neonatal metabolic acidosis was analyzed.
RESULTS: Fifty-three (27%) fetuses had non-reassuring fetal status requiring emergency delivery, whereas 21 (11%)
Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПолный текст не найденПеревод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
OBJECTIVE: To compare the blood flow in sequential and individual saphenous vein grafts (SVGs) and to analyze the influence of the location of the target vessel in off-pump coronary artery bypass grafting (OPCAB).
METHODS: A total of 464 SVGs in 412 patients receiving OPCAB were nested into individual SVG (n=206), double (n=241) or triple sequential SVG (n=15), and analyzed.
RESULTS: The blood flow in double and triple SVGs was significantly higher than in individual SVGs [(43.4±22.5), (43.7±19.2) and (28.9±18.7) mL/min, respectively, P<0.001, P=0.047]. There were no differences between flow
СтатьяПолный текст не найденПеревод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
BACKGROUND: Birth trauma may lead in infants to developmental delay, cerebral palsy, epilepsy and complications with increasing risk of the death. Several complications are of vascular origin. The aim of the study was the assessment of the transcranial Doppler-sonographic (TCD) measurement of cerebral blood flow in infants with perinatal CNS pathology.
MATERIAL AND METHODS: 14 infants, 9 females and 5 males, within 12 premature infants, with the CNS perinatal pathology were examined. In children during the neonatal period respiratory distress syndrome, sepsis, apnoe and seizures were also obs
Оценочное исследованиеСтатьяПоиск полного текста в очередиПеревод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
INTRODUCTION: Ventriculoarterial coupling (VAC), traditionally assessed using the invasive "gold standard" Ea/Ees ratio (arterial elastance to end-systolic elastance), is clinically important but requires approximations that are impractical at the bedside. Oscillatory power fraction (OPF), defined as the ratio of oscillatory to total hydraulic power and derived from synchronized aortic flow-pressure measurements, has been proposed as a pragmatic VAC surrogate. This study aimed to clarify the possible correlation between VAC and OPF in pharmacologically induced hemodynamic extremes.
METHODS: I
СтатьяПолный текст не найденПеревод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
BACKGROUND AND OBJECTIVES: Blood-brain barrier (BBB) disruption was found to be critical in the pathogenesis of reversible cerebral vasoconstriction syndrome (RCVS). We hypothesized that increased central arterial stiffness, resulting in the excessive transmission of central pulsatile flow to the dysregulated cerebral microcirculation, may contribute to the disruption of BBB.
METHODS: This is a cross-sectional study. Participants with RCVS in the acute phase were recruited from both outpatient and inpatient settings between January 2018 and September 2020. The diagnosis was established based …
СтатьяПоиск полного текста в очередиПеревод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
BACKGROUND: Significant right ventricular failure (RVF) complicating left ventricular assist device (LVAD) placement has been reported at 10-30%. Although primarily indicated for left ventricular failure, ventricular assist devices (VADs) have become utilized in a biventricular setup to combat right ventricular failure (RVF) following LVAD implantation. With the advent of continuous-flow LVADs (CF-LVADs) superseding their pulsatile predecessors, the shift towards CF-biventricular assist devices (CF-BiVADs) come with the prospect of improved outcomes over previous pulsatile BiVADs. We aim to re
СтатьяПоиск полного текста в очередиПеревод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
OBJECTIVE: With the developments in vascular ultrasound technology, the opportunity has arisen to examine in greater detail the distribution … small proportion, but treadmill walking led to the recruitment of most perforators with spontaneous pulsatile flow at greatly increased velocities. The estimated total perforator volume flow could be increased by up to five-fold and accounting for as much as 80 mL/min in a leg. Isometric foot plantar flexion stopped any spontaneous flow and, on relaxation, resul …
СтатьяПоддержка исследования: вне правительства СШАПолный текст не найденПеревод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
BACKGROUND: Diffuse correlation spectroscopy (DCS) is a non-invasive optical technique that enables continuous blood flow measurements in various organs, including the brain. DCS quantitatively measures blood flow from temporal fluctuations in the intensity of diffusely reflected light caused by the dynamic scattering of light from moving red blood cells within the tissue.
METHODS: We performed bilateral cerebral blood flow (CBF) measurements using a custom DCS device in patients undergoing neuroendovascular interventions for acute ischemic stroke. Experimental, clinical, and imaging data wer
СтатьяПоиск полного текста в очередиПеревод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
OBJECTIVES: To compare trends in the anterior cerebral artery (ACA) Doppler markers of vascular flow for neonates with a congenital heart defect (CHD) with and without diastolic systemic steal during the first 7 days of life.
METHODS: Prospective study recruiting newborns (≥35 weeks of gestation) with a CHD. Doppler ultrasound and echocardiography were performed daily from day 1 to 7. The cohort was divided into the presence/absence of holo-diastolic retrograde flow in the postductal aorta ("retrograde") on the last-available echocardiogram. Data extractors were masked to retrograde status. M
СтатьяПолный текст не найденПеревод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.