Публикации на разных языках · PubMed, Europe PMC и данные издателей через Crossref · 301 с найденным полным текстом
Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association2024eng
Bacterial contamination as a result of suture contamination may be associated with rotator cuff retear or impaired tendon healing after rotator cuff repair. This represents a potential new area of focus and intervention. Despite an array of rotator cuff repair techniques, from varying suture configurations and double-row repairs to biologic adjuncts and patches, a substantial proportion of repairs do not heal or go on to retear. Decades of research have been dedicated to identifying risk factors for these failures and mitigating their influence. Yet, as we transitioned from open to arthroscopi
Редакционная статьяКомментарийПолный текст не найденПеревод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association2024eng
PURPOSE: To evaluate the correlation between suture contamination and rotator cuff tendon retear after arthroscopic rotator cuff repair.
ME … n.
CONCLUSIONS: The matched-pair analysis revealed that the presence of bacterial contamination on sutures was associated with a higher risk of retear on magnetic resonance imaging following arthroscopic rotator cuff repair.
LEVEL OF EVIDENCE: Level III, retrospective cohort study.
СтатьяПолный текст не найденПеревод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
OBJECTIVE: To investigate the efficacy of Endobutton plate combined with high-strength suture Nice knot fixation in the treatment of distal clavicular fractures with coracoclavicular ligament injuries.
METHODS: A retrospective analysis was performed on 43 patients who sustained distal clavicular fractures along with injuries to the coracoclavicular ligament. These patients were treated between January 2017 and December 2023. The fractures were classified according to the fixation method: high-strength Nice knot suture fixation (experimental group, n = 23) and acromioclavicular Kirschner wire
СтатьяПоиск полного текста в очередиПеревод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
The anterior cruciate ligament (ACL) is the primary soft-tissue structure for anterior stabilization of the knee and is one of the most frequently injured structures. The incidence of ACL injuries in children and adolescents ranges from 92 to 151 per 100,000 person-years. The choice of surgical treatment for this population group is controversial, with a widespread concern that adult reconstruction techniques may damage the epiphyseal plate, compromise growth, or cause deformity. In this article, we describe a physeal-sparing, all-inside ACL reconstruction technique for skeletally immature pat
СтатьяПолный текст не найденПеревод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association2024eng
PURPOSE: To intraoperatively evaluate the ability of anterior cruciate ligament (ACL) primary repair (ACLPR) to restore anterior tibial translation (ATT) at time zero and to assess the influence of additional suture augmentation (SA) on ATT.
METHODS: Patients with proximal ACL tears undergoing arthroscopic ACLPR with dual-suture anchor fixation were included in this time-zero clinical study. Laxity measurements were taken with a digital arthrometer to evaluate ATT stability preoperatively in the office (T0) as a standardized diagnostic tool, preoperatively under anesthesia (T1), at time zero
СтатьяПоиск полного текста в очередиПеревод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
BACKGROUND: The purpose of this study is to explore whether decreasing the number of sutures can improve the quality of life after inferior third molar extraction.
MATERIAL AND METHODS: This study used a three-arm randomized design that included 90 individuals. Patients were randomized and divided into three groups-the airtight suture group (traditional), the buccal drainage group, and the no-suture group. Postoperative measurements, including treatment time, visual analog scale, questionnaire on postoperative patient quality of life, and details about trismus, swelling, dry socket, and other…
Рандомизированное исследованиеСтатьяПоиск полного текста в очередиПеревод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
BACKGROUND: Trans-calcaneal suture technique is an economical and effective method for repairing Achilles tendon sleeve avulsion. Whether cancellous bone fixation upon this technique could accelerate tendon-to-bone healing is unknown. The purpose of this study is to compare the effect of cortical versus cancellous bone fixation on tendon-bone healing with a novel rat trans-calcaneal suture model.
METHODS: Trans-calcaneal suture treatment was carried out on the right hindlimb in male Sprague-Dawley rats (N = 80). They were randomly divided into the cortical group (Achilles fixed to the calcane
СтатьяПолный текст не найденПеревод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association2023eng
PURPOSE: To compare the 2 Latarjet fixation techniques-screw fixation (SF) versus suture button (SB) -for clinical, biomechanical, and radiologic outcomes.
METHODS: A systematic review was conducted in accordance with Preferred Reporting Items for Systematic and Meta-Analyses guidelines using MEDLINE and Embase databases and was prospectively registered on PROSPERO. Only comparative clinical and biomechanical studies of Latarjet with SF and SB were included. Studies were appraised using the Methodical Index for Non-Randomised Studies (MINORS) tool.
RESULTS: Eleven studies met eligible criter
Систематический обзорСтатьяСравнительное исследованиеПоиск полного текста в очередиПеревод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
BACKGROUND: Large-bore arteriotomies can be percutaneously closed with suture-based or plug-based vascular closure device (VCD) strategies. The efficacy of both techniques remains controversial.
AIMS: We conducted a meta-analysis of comparative studies between both VCD strategies, focusing on the most commonly applied VCDs (MANTA and ProGlide).
METHODS: We searched MEDLINE, the Cochrane Central Register of Controlled Trials and Google scholar for observational studies (OS) and randomized controlled trials (RCT) comparing vascular closure with the MANTA-based and the ProGlide-based technique.
МетаанализСтатьяПоиск полного текста в очередиПеревод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Much is known about the biomechanical performance of various types of suture anchors commonly used for labral fixation in the shoulder; however, similar studies in the hip are less common. We sought to compare all-suture and polyether ether ketone small-diameter anchors in the setting of labral repair during hip arthroscopy, with and without acetabuloplasty. We hypothesized that the biomechanical properties of the all-suture group when compared to polyether ether ketone anchors would be similar amongst native acetabula and significantly less following acetabuloplasty and that pullout forces wo
СтатьяПоддержка исследования: вне правительства СШАПоиск полного текста в очередиПеревод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
PURPOSE: Three cases of dislocation of a Gore-Tex scleral-sutured EnVista intraocular lens are reported. The tensile strength of the lens eyelets under two suturing methods is assessed. Pursuant surgical considerations are discussed.
METHODS: A chart review was performed to identify cases of scleral-sutured EnVista lens dislocations. In addition, six EnVista lenses were suspended in a balanced salt solution tank, tied either with suture over haptic or simple pass technique. Eyelet tensile strength was calculated by gradual addition of weights. Eyelet fracture position and width were measured.
СтатьяПолный текст не найденПеревод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
INTRODUCTION: Only a few case reports regarding pediatric posterior cruciate ligament (PCL) ruptures without bone avulsion exist in the literature. The present study aims to share our experience in the diagnosis, treatment, and prognosis of a child with a proximal PCL tear.
MATERIALS AND METHODS: This article reports a 5-year-old female diagnosed with a proximal PCL tear. The ruptured PCL was repaired with an all-epiphyseal suture tape augmentation (STA) without evidence of growth plate violation.
RESULTS: The suture tape was removed under arthroscopy and revealed the PCL was re-attached at
ОбзорКлинический случайСтатьяПоддержка исследования: вне правительства СШАПолный текст не найденПеревод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
OBJECTIVE: To investigate the feasibility and effectiveness of "tail compression fixation+suture bridge" technology under shoulder arthroscopy for treating primary tear in medial enthesis of rotator cuff.
METHODS: The clinical data of 11 patients with primary tear in medial enthesis of rotator cuff who met the selection criteria between October 2020 and October 2022 were retrospectively analyzed, including 3 males and 8 females, aged 39-79 years, with an average of 61.0 years. Rotator cuff injury was caused by traumatic fall in 8 cases, and the time from injury to admission was 1-4 months, wi
Аннотация на английскомСтатьяПоиск полного текста в очередиПеревод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
UNLABELLED: The aim of this study was to estimate the time needed for patients with Maisonneuve fractures to return to routine activities, after treatment with a suture-button system stabilization combined with plate and arthroscopic assistance (SBPAA).
METHODS: The study included 13 patients treated at our surgical department from January 2018 to June2022. Specific radiographical follow-up and periodic checks were performed in a short -to-medium term period, to evaluate syndesmosis evolution and tibiofibular overlap with medial clear space (MCS).
RESULTS: Progressive recovery and improvemen
СтатьяПоиск полного текста в очередиПеревод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association2023eng
PURPOSE: To perform a systematic review to compare clinical outcomes, complications, and reoperation rates of patients undergoing the Latarjet procedure with screw vs suture-button fixation.
METHODS: A systematic review was performed by searching PubMed, the Cochrane Library, and Embase to identify clinical studies directly comparing screw vs suture-button fixation for the Latarjet procedure. The search terms used were shoulder screw suture button. Patients were evaluated based on reoperation rate, complication rate, recurrent instability, radiologic outcomes, and patient-reported outcomes. G
Систематический обзорСтатьяСравнительное исследованиеПолный текст не найденПеревод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
IMPORTANCE: Lisfranc injuries remain a significant, but often misdiagnosed, orthopaedic injury. Alongside the traditional methods of surgical fixation, including arthrodesis and open reduction and internal fixation with screws, suture button fixation is an emerging technique.
OBJECTIVES: The purpose of this study is to investigate the efficacy of suture button fixation for treatment of Lisfranc injuries through a systematic review.
EVIDENCE REVIEW: A comprehensive literature review was conducted according to the preferred reporting items for systematic reviews using PubMed, Embase, Web of Sc
Систематический обзорСтатьяПолный текст не найденПеревод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
The urgency of the problem of combined pathology of the anal canal and rectum is quite high due to the lack of a unified approach to surgical treatment of this category of patients. The aim of the study was to conduct a comparative morphological assessment of postoperative wound healing in patients with combined anorectal pathology after combined operations using different types of suture material, as well as modern high-frequency electrosurgery and radio-wave surgery devices. The dynamics of the wound process under the influence of caprosin (3/0) and polysorb (3/0) was performed on 60 patient
СтатьяПоиск полного текста в очередиПеревод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
This report describes two cases of atopic dermatitis patients with scleral perforation after recurrent scleritis induced by suture exposure after scleral-sutured posterior chamber intraocular lens (PC-IOL) implantation. The first patient was a 41-year-old man (case 1), and the second was a 46-year-old man (case 2). Both had a history of atopic dermatitis and scleral-sutured intraocular lens (IOL) implantation. Scleritis recurred at the suture site after scleral-sutured IOL implantation in both patients. Although the scleritis was controlled by topical and/or systemic anti-inflammatory drugs, t
Клинический случайСтатьяПолный текст не найденПеревод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
BACKGROUND: Transosseous tunnel (TO) repair is considered the gold standard for patellar tendon rupture; however, suture anchor (SA) repair has emerged as a viable alternative in recent years. Although both these techniques are used widely in clinical practice, the most biomechanically optimal construct for patellar tendon repair remains unknown.
PURPOSE: To examine published studies on the biomechanical properties of TO and SA fixation for patellar tendon repair in terms of ultimate load to failure and cyclic gap formation. The null hypothesis was that there would be no significant differenc
СтатьяОбзорПолный текст не найденПеревод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Anastomotic leakage (AL) is a major cause of postoperative morbidity and mortality in the treatment of colorectal cancer. The aim of this study was to investigate an innovative and convenient technique of laparoscopic demucositized suture the overlapping point of the "dog ear" area after the double stapling anastomosis (lds-DSA), as an improved alternative for conventional DSA, and whether it could reduce the AL rate in laparoscopic anterior resection (Lapa-AR). Between January 2018 and December 2020, a total of 245 patients who underwent Lapa-AR for the treatment of adenocarcinoma of the sigm
СтатьяПоиск полного текста в очередиПеревод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.