m+Medelevator.RU
← Поиск публикаций
Congenital heart disease · 2018

Rhythm disturbances and treatment strategies in children with congenitally corrected transposition of the great arteries.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Kasar Taner, Ayyildiz Pelin, Tunca Sahin Gulhan, Ozturk Erkut, Gokalp Selman, Haydin Sertac, Guzeltas Alper, Ergul Yakup

Аннотация

BACKGROUND: We aimed to evaluate rhythm abnormalities in cases of congenitally corrected transposition of the great arteries (ccTGA) and associated treatment strategies.

PATIENTS AND METHODS: This retrospective cohort study included 65 pediatric patients with ccTGA who were admitted to the clinic between 2009 and 2017. The patients were divided into two groups, and surgical data, Holter electrocardiographic (ECG) recordings, ECG recordings, electrophysiological data, and device implantation data on the two groups were compared.

RESULTS: Group I (n = 53, 82%) consisted of patients with significant associated lesions, and Group II (n = 12, 18%) consisted of those with minor or no associated lesions (isolated ccTGA). Rhythm abnormalities were diagnosed in 22 (34%) of the patients based on initial ECG findings and Holter ECG recordings. Eleven (17%) of these patients had atrioventricular (AV) block of different degrees, and the other 11 (17%) had supraventricular arrhythmia (SVA). The median follow-up was 49 months (range, 9-89 months), and the rhythm remained normal in 26 (42%) of the patients. Three patients died on follow-up. Of 40 patients with normal initial findings, nine required pacemaker implantation due to complete heart block, and SVA developed in seven patients on follow-up. No ventricular tachycardia was seen initially or on follow-up. Ablation was performed in four patients. During the follow-up period, pacemakers were implanted in 12 (23%) of patients in Group I and 4 (33%) of patients in Group II due to complete heart block. Cardiac resynchronization therapy (CRT) was performed in four patients due to systemic ventricular dysfunction. Notably, all four of these patients had a pacemaker implanted postoperatively.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты