OBJECTIVE

To investigate the long-term surgical outcome of Brown syndrome using an intraoperative adjustable superior oblique (SO) tendon suture spacer.

DESIGN

Retrospective case series.

PARTICIPANTS

Thirteen patients with congenital unilateral Brown syndrome operated on at the Wolfe Eye Clinic from 2001 through 2007.

METHODS

Retrospective analysis of consecutive patients managed with the SO suture spacer followed up for at least 10 months.

MAIN OUTCOME MEASURES: Surgical intervention for patients having severe or moderate forms of Brown syndrome. Postoperative effect on abnormal head posture, vertical strabismus in primary gaze, vertical strabismus into affected side gaze, and elevation in adduction.

RESULTS

The mean duration of follow-up was 30 months (range, 10-72 months). Abnormal head posture improved from 13 degrees (range, 0 degrees -30 degrees ) to 0.4 degrees (range, 0 degrees -5 degrees ). Vertical strabismus in primary gaze improved from -10Delta (range, 0Delta to -35Delta) to 2.8Delta (range, -16Delta to 16Delta). Vertical in side gaze improved from -20Delta (range, -35Delta to -8Delta) to -1.5Delta (range, -20Delta to 18Delta). Elevation in adduction improved from -3.5 (range, -4 to -2) to -0.4 (range, -2 to 4). Four patients had an overcorrection and 2 patients experienced an increasing late effect. In no patient did a late under correction develop.

CONCLUSIONS

The SO suture spacer procedure alleviated abnormal head positions in patients with Brown syndrome by improving vertical strabismus in primary position and in the affected field of gaze while avoiding overcorrection in contralateral gaze. The benefits of the procedure persisted over time.

Для цитирования: Suh Donny W, Oystreck Darren T, Hunter David G. Long-term results of an intraoperative adjustable superior oblique tendon suture spacer using nonabsorbable suture for Brown Syndrome.. Ophthalmology. 2008. DOI: 10.1016/j.ophtha.2008.04.007.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.