Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2015

Data on procedural handling and complications of pulmonary vein isolation using the pulmonary vein ablation catheter GOLD®.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Leitz Patrick, Güner Fatih, Wasmer Kristina, Foraita Philip, Pott Christian, Dechering Dirk Georg, Zellerhoff Stephan, Kochhäuser Simon, Lange Philipp Sebastian, Eckardt Lars, Mönnig Gerold

Аннотация

AIMS: The second-generation multi-electrode-phased radiofrequency pulmonary vein ablation catheter (PVAC GOLD(®)) was redesigned with the intent to improve its safety and efficacy.

METHODS AND RESULTS: Using a prospectively designed single-centre database, we retrospectively analysed 128 consecutive patients (102 paroxysmal and 43 female) who underwent their first pulmonary vein isolation with the PVAC GOLD(®). The analysis focused on procedural data as well as in-hospital complications. Baseline characteristics of the patient collective were as follows: mean age 57.9 years, mean CHA2DS2-VASC was 1.73 ± 1.30; structural heart disease was present in seven patients. The PVAC GOLD(®) exhibited procedure durations of 123.1 min ± 27.9, duration of energy delivery was 18.3 min ± 11.4, and fluoroscopy duration was 16.0 min ± 7.7. The redesigned catheter shows major complication [major bleeding, transitory ischaemic attack (TIA), and pericardial tamponade] rates of 2.3% (n = 3). The overall rate of adverse events was 5.4% (n = 7). Bleeding complications were observed in three patients (2.3%), in particular there were two cases (1.6%) of minor bleeding and one case (0.8%) of major bleeding. Two patients suffered pericardial effusion, but there was no need for pericardiocentesis. Besides one TIA, there was no other thrombo-embolic event. Furthermore, one case of post-procedural fever was observed. No deaths, stroke, or haemorrhagic shock occurred. Of the 510 pulmonary veins, 508 could be reached with the PVAC GOLD(®) device using a non-steerable long sheath.

CONCLUSION: The PVAC GOLD(®) seems to have an acceptable safety profile. The handling is comparable with the previous generation PVAC(®).