DOI 10.32641/rchped.v91i2.1144

Медицинская библиотека · Revista chilena de pediatria · 2020

Diaphragm pacing in a pediatric patient with Acquired Central Hypoventilation syndrome.

Varela O Javier, Sepúlveda I Germán, Sepúlveda C Jose, Acuña L Renato, Pizarro T Gustavo, Maldonado U Viviana, Alvarado G Alejandra

Клинический случайСтатьяПеревод в очереди

Аннотация

INTRODUCTION

Diaphragmatic pacemaker is a device that reduces or eliminates the need of mechanical ventilation in patients with chronic respiratory failure who keep the phrenic nerve-diaphragm axis intact, as long as they do not present intrinsic lung disease. Although its implantation has been practiced for deca des, its use is not widespread and to date, there is little published literature about it, mostly related to high spinal cord injury and congenital central hypoventilation syndrome.

OBJECTIVE

To describe an experience of diaphragmatic pacemaker implantation in a pediatric patient with acquired cen tral hypoventilation syndrome.

CLINICAL CASE: Female patient with central hypoventilation syndrome secondary to ischemic brainstem lesion as a result of ventriculoperitoneal shunt malfunction. For this reason, for 5 years she was supported by inpatient mechanical ventilation. At 7 years of age, a diaphragmatic pacemaker was implanted by thoracoscopic surgery, which allowed, after a period of rehabilitation and respiratory conditioning, mechanical ventilation withdrawal, and hospital dischar ge.

CONCLUSIONS

Diaphragmatic pacemaker is a feasible, potentially safe, and cost-effective option for decreasing or eliminating mechanical ventilation dependence and improve life quality in patients with acquired central hypoventilation syndrome.

Для цитирования: Varela O Javier, Sepúlveda I Germán, Sepúlveda C Jose, Acuña L Renato, Pizarro T Gustavo, Maldonado U Viviana, Alvarado G Alejandra. Diaphragm pacing in a pediatric patient with Acquired Central Hypoventilation syndrome.. Revista chilena de pediatria. 2020. DOI: 10.32641/rchped.v91i2.1144.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.