m+Medelevator.RU
← Поиск публикаций
Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography · 2015

Three-Dimensional Echocardiographic En Face Views of Ventricular Septal Defects: Feasibility, Accuracy, Imaging Protocols and Reference Image Collection.

СтатьяМногоцентровое исследованиеПоддержка NIH: внешняя программаНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Cossor Waseem, Cui Vivian Wei, Roberson David A

Аннотация

BACKGROUND: Ventricular septal defect (VSD) is the most common congenital cardiac anomaly. Accurate assessment is critical for planning treatment. Recent advances in three-dimensional (3D) echocardiography have improved image quality and ease of use.

METHODS: The feasibility and accuracy of three specific 3D echocardiographic protocols to demonstrate en face views of VSDs were analyzed in a retrospective review of 100 consecutive patients. Sixty-four patients underwent transthoracic echocardiography and 36 transesophageal echocardiography. Types of VSDs included 34 muscular, 32 perimembranous, 18 malaligned, 11 inlet, four outlet, and one acquired. Ages ranged from 1 day to 77 years, and body weights from 3 to 92 kg. Three-dimensional echocardiographic full-volume mode with standard XYZ and adjustable plane cropping, 3D full-volume mode with iCrop, and narrow-sector live 3D protocols were compared for feasibility and accuracy to obtain a diagnostic-quality en face view of a VSD.

RESULTS: The success rate for obtaining a high-quality en face image for the three protocols was 100% for full-volume mode with iCrop, 97% for full-volume standard mode, and 94% for narrow-sector live 3D mode. The ability of both full-volume mode with iCrop and full-volume standard mode to demonstrate a VSD was slightly better than that of narrow-sector live 3D mode (P < .001 for both vs narrow-sector live 3D mode). In all patients, the type, size, and location of the VSD were demonstrated accurately by two or more of the protocols.

CONCLUSIONS: Three-dimensional echocardiography of VSDs is feasible and accurate in most patients using defined protocols. The protocols are described and illustrated in detail, and a reference 3D image collection is presented.

Предметные рубрики MeSH