MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.prosdent.2025.05.009

Медицинская библиотека · The Journal of prosthetic dentistry · 2025

In vitro comparison between complete arch abutment-level implant impressions with photogrammetry, grammetry, and intraoral scanning.

Prott Lea S, Atria Pablo J, Maluf Caroline V, Blatz Markus B, Conejo Julian

СтатьяСравнительное исследованиеПеревод в очереди

Аннотация

STATEMENT OF PROBLEM: Photogrammetry (PG) has emerged as a promising recording technique for fabricating implant-supported prostheses. However, the existing evidence on the accuracy of dental PG devices is still limited.

PURPOSE: The purpose of this in vitro study was to evaluate the trueness and precision of a newly introduced advanced PG device (MicronMapper; SIN 360) by comparing it with grammetry and intraoral scanning.

MATERIAL AND

METHODS

Four implants (BioHorizons) were placed in an edentulous mandibular model. Multi-unit abutments (BioHorizons) were positioned and tightened to 30 Ncm. A digital reference cast (Control group) was obtained by scanning the model with a laboratory scanner (inEosX5; Dentsply Sirona). Three test groups were evaluated: PS (Primescan), PS-OS (Primescan and OptiSplint), and PG (MicronMapper; SIN 360). Test files were superimposed with the reference file (trueness) and pairwise within groups (precision) using a 3D evaluation software program (Geomagic Control X). Root mean square (RMS) values were calculated. Analysis of variance (ANOVA) was used to analyze differences in RMS values among groups (α=.05), followed by the Tukey post hoc test.

RESULTS

For trueness, group PG showed the lowest mean ±standard deviation RMS values (20.5 ±0.6 µm), followed by PS-OS (30.9 ±16.8 µm) and PS (56 ±0.7 µm). A statistically significant difference was found between groups PG and PS (P<.001), as well as PS-OS and PS (P=.004). For precision, the lowest RMS values were detected in group PG (6 ±1.2 µm), followed by PS (9.5 ±3.3 µm) and PS-OS (23.3 ±22.3 µm). No statistically significant differences were detected among the test groups in terms of precision (P=.192).

CONCLUSIONS

Photogrammetry obtained the best accuracy. Grammetry improves the trueness; however, it appears to have no positive impact on the precision of complete arch implant recordings.

Для цитирования: Prott Lea S, Atria Pablo J, Maluf Caroline V, Blatz Markus B, Conejo Julian. In vitro comparison between complete arch abutment-level implant impressions with photogrammetry, grammetry, and intraoral scanning.. The Journal of prosthetic dentistry. 2025. DOI: 10.1016/j.prosdent.2025.05.009.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.