MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jaapos.2023.08.014

Медицинская библиотека · Journal of AAPOS : the official publication of the American Association for Pediatric Ophthalmology and Strabismus · 2023

Performance of virtual reality game-based automated perimetry in patients with childhood glaucoma.

Wang Bo, Alvarez-Falcón Samuel, El-Dairi Mays, Freedman Sharon F

СтатьяПеревод в очереди

Аннотация

PURPOSE: To evaluate VisuALL, a game-based automated perimetry device, utilizing virtual reality (VR) goggles, in a cohort of patients with childhood glaucoma.

METHODS

In this prospective series, the results of consecutive patients with childhood glaucoma performing both VisuALL VR field (VRF) and Humphrey visual field (HVF) 24-2 testing were compared. A masked ophthalmologist graded both VRF and HVF tests for field defects (three clustered abnormal points in total or pattern deviation plot). VRF testing was performed binocularly and with the child's own spectacles. The two devices were assessed with respect to agreement of (1) global indices, such as mean deviation (MD) and pattern standard deviation (PSD), (2) point-by-point sensitivity, and (3) the ability to detect visual field defects determined by a grader.

RESULTS

A total of 39 children (77 eyes) were enrolled, with mean age 14.1 ± 3.6 years; 3 patients (5 eyes) could not complete the HVF. Average HVF MD was -6.3 ± 6.4 dB. There was strong correlation between VRF and HVF for MD (R = 0.68, P < 0.001), PSD (R = 0.78, P < 0.001), and point-by-point sensitivity (R = 0.63, P < 0.001). Bland Altman analysis showed no systematic difference between VRF and HVF in assessing MD and PSD. Of 72 eyes having results for both modalities, 63 (87.5%) had agreement between VRF and HVF with respect to the presence/absence of any field defect, and 52 (72.2%) had agreement regarding the presence/absence of fixation-threatening field loss.

CONCLUSIONS

VRF is comparable to the gold standard HVF in both identification and quantification of visual field deficits in pediatric glaucoma patients and may offer a valuable supplement or alternative to standard automated perimetry.

Для цитирования: Wang Bo, Alvarez-Falcón Samuel, El-Dairi Mays, Freedman Sharon F. Performance of virtual reality game-based automated perimetry in patients with childhood glaucoma.. Journal of AAPOS : the official publication of the American Association for Pediatric Ophthalmology and Strabismus. 2023. DOI: 10.1016/j.jaapos.2023.08.014.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.