DOI 10.1016/j.ejrad.2026.112995
Unsedated non-contrast MRI for suspected pediatric appendicitis: A prospective study of diagnostic performance, interobserver agreement, and clinical impact.
Аннотация
PURPOSE: To evaluate the diagnostic accuracy, interobserver agreement, and clinical feasibility of an ultra-rapid, unsedated, non-contrast magnetic resonance imaging (MRI) protocol for suspected appendicitis in children, emphasizing negative appendectomy rate and alternative diagnosis detection.
METHODS
This prospective STARD-2015-compliant study included 73 children (11.4 ± 3.2 years; 57.5% male) with suspected appendicitis. All underwent non-contrast MRI without sedation on a 1.5 Tesla scanner. The protocol included T2-weighted turbo spin-echo sequences and diffusion-weighted imaging (b-values 150, 800, 1000 s/mm2) with apparent diffusion coefficient maps. Mean acquisition time was 9.2 ± 1.8 min. Reference standard was histopathology or clinical follow-up. Interobserver agreement was assessed using Cohen's kappa (κ).
RESULTS
Appendicitis prevalence was 32.9% (24/73). MRI showed 95.8% sensitivity (95% CI: 79.8-99.3%), 95.9% specificity (95% CI: 86.3-98.9%), and area under the curve of 0.959. Positive and negative predictive values were 92.0% and 97.9%, respectively. Appendix visualization was 100% in appendicitis vs. 57.1% in non-appendicitis (p < 0.001). Fecalith was 100% specific for appendicitis (45.8% vs. 0%, p < 0.001). Restricted diffusion occurred in 66.7% vs. 12.2% (p < 0.001). Interobserver agreement was almost perfect (κ = 0.937; p < 0.001). All examinations were completed without sedation. Negative appendectomy rate was 4.3% (1/23). Alternative diagnoses were identified on MRI in 38.8% (19/49) of patients without appendicitis.
CONCLUSION
These findings suggest that rapid non-contrast MRI is a promising radiation-free, sedation-free option for children aged ≥ 5 years with suspected appendicitis. However, implementation into routine pediatric emergency pathways should await prospective multicenter validation to confirm reproducibility across diverse settings, scanner types, and radiologist experience levels.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.