MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00417-012-2082-9

Медицинская библиотека · Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie · 2012

In vitro effect of corneal collagen cross-linking on corneal hydration properties and stiffness.

Kontadakis Georgios A, Ginis Harilaos, Karyotakis Nikolaos, Pennos Alexandros, Pentari Iro, Kymionis George D, Pallikaris Ioannis G

СтатьяПеревод в очереди

Аннотация

BACKGROUND

The purpose of this study is to evaluate in-vitro the immediate effect of corneal collagen cross-linking (CXL) on corneal hydration and stiffness.

METHODS

Forty-two corneal buttons from freshly enucleated porcine eyes were immersed in riboflavin 0.1% in dextran 20% dilution for 3 h in order for their hydration to reach equilibrium. Corneal buttons where divided into two groups; the first group was stored in dark conditions while the other group was irradiated with UV radiation (370 nm) for 30 min to simulate CXL according to the clinically applied protocol. After irradiation, all corneas were immersed in dextran 20% solution for 3 additional hours. Subsequently, each button underwent weighing, thickness measurement, and was mounted in a special device for the measurement of force versus deformation by compression. Finally, all corneal buttons were dehydrated for 48 h in a desiccating oven set at 62 °C and weighed again to obtain their dry mass. Hydration (%) of each button was calculated.

RESULTS

Mean corneal hydration in the irradiated and the non-irradiated group of corneas was 69.8 and 72.2%, respectively (p < 0.001). Differences in thickness and compressibility were not statistically significant. Thickness and hydration were positively correlated (Pearson's r = 0.714, p < 0.001).

CONCLUSIONS

CXL causes corneal dehydration that can be detected immediately after the procedure. This phenomenon may contribute to increased mechanical stiffness of the cornea. A change in stiffness by means of compressibility could not be detected in porcine corneas.

Для цитирования: Kontadakis Georgios A, Ginis Harilaos, Karyotakis Nikolaos, Pennos Alexandros, Pentari Iro, Kymionis George D, Pallikaris Ioannis G. In vitro effect of corneal collagen cross-linking on corneal hydration properties and stiffness.. Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie. 2012. DOI: 10.1007/s00417-012-2082-9.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.