MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/s0886-3350(02)01604-8

Медицинская библиотека · Journal of cataract and refractive surgery · 2003

Intraoperative and postoperative complications of Cionni endocapsular ring implantation.

Moreno-Montañés Javier, Sainz Carmen, Maldonado Miguel J

СтатьяПеревод в очереди

Аннотация

PURPOSE: To analyze the intraoperative and postoperative complications of Cionni ring implantation in eyes with a subluxated lens or zonular weakness.

SETTING

Departamento de Oftalmología, Clínica Universitaria de Navarra, Universidad de Navarra, Pamplona, Spain.

METHODS

This case series comprised 7 eyes of 5 patients with a subluxated lens or zonular weakness secondary to Marfan's syndrome (n = 2), traumatic cataract (n = 2), or megalocornea (n = 1) or of unknown etiology (n = 2). An AcrySof (Alcon) foldable intraocular lens (IOL) was implanted in all eyes. A 2-eyelet Cionni ring was implanted in 1 eye and a 1-eyelet Cionni ring, in 6 eyes. The Cionni ring was secured in position with a transscleral suture knotted to the ring's hook, avoiding peripheral perforation of the capsular bag.

RESULTS

In 1 eye, corectopia was inadvertently produced by passing the suture needle through the iris root; lens subluxation temporarily increased during ring rotation and implantation. However, after the transscleral suture was tightened, capsular bag centration was excellent. In the eye with megalocornea, traction from the 2 hooks tore the edge of the anterior capsule rim. The most frequent postoperative complication was posterior capsule opacification, which occurred in 5 eyes, 2 of which required a neodymium:YAG posterior capsulotomy. After 1 year, the Cionni ring continued to provide excellent stability and capsular bag and IOL positioning in all cases.

CONCLUSIONS

Results indicate that Cionni ring implantation is an acceptable procedure to correct limited lens subluxation, preserves the capsular bag, and has few significant complications.

Для цитирования: Moreno-Montañés Javier, Sainz Carmen, Maldonado Miguel J. Intraoperative and postoperative complications of Cionni endocapsular ring implantation.. Journal of cataract and refractive surgery. 2003. DOI: 10.1016/s0886-3350(02)01604-8.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.