Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists · 2004
Novel intravascular ultrasound-guided method to create transintimal arterial communications: initial experience in peripheral occlusive disease and aortic dissection.
СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Saket Ramin R, Razavi Mahmood K, Padidar Arash, Kee Stephen T, Sze Daniel Y, Dake Michael D
Аннотация
PURPOSE: To report our experience using a commercially available catheter-based system equipped with an intravascular ultrasound (IVUS) transducer to achieve controlled true lumen re-entry in patients undergoing subintimal angioplasty for chronic total occlusions (CTO) or aortic dissections.
METHODS: During an 8-month period, 10 patients (6 men; mean age 73.4 years) with lower extremity (LE) ischemia from CTOs (n=7) or true lumen collapse from aortic dissections (n=3) were treated. Subintimal access and controlled re-entry of the CTOs were performed with a commercially available 6.2-F dual-lumen catheter, which contained an integrated 64-element phased-array IVUS transducer and a deployable 24-G needle through which a guidewire was passed once the target lumen was reached. The occluded segments were balloon dilated; self-expanding nitinol stents were deployed. In the aortic dissections, fenestrations were performed using the same device, with the IVUS unit acting as the guide. The fenestrations were balloon dilated and stented to support the true lumen.
RESULTS: Time to effective re-entry ranged from 6 to 10 minutes (mean 7) in the CTOs; antegrade flow was restored in all 7 CTOs, and the patients were free of ischemic symptoms at up to 8-month follow-up. In the aortic dissection cases, the fenestrations equalized pressures between the lumens and restored flow into the compromised vessels. There were no complications related to the use of this device in any of the 10 patients.
CONCLUSIONS: Our preliminary results demonstrate the feasibility of using this catheter-based system for subintimal recanalization with controlled re-entry in CTOs and for aortic flap fenestrations in aortic dissections. This approach can improve the technical success rate, reduce the time of the procedure, and minimize potential complications.
METHODS: During an 8-month period, 10 patients (6 men; mean age 73.4 years) with lower extremity (LE) ischemia from CTOs (n=7) or true lumen collapse from aortic dissections (n=3) were treated. Subintimal access and controlled re-entry of the CTOs were performed with a commercially available 6.2-F dual-lumen catheter, which contained an integrated 64-element phased-array IVUS transducer and a deployable 24-G needle through which a guidewire was passed once the target lumen was reached. The occluded segments were balloon dilated; self-expanding nitinol stents were deployed. In the aortic dissections, fenestrations were performed using the same device, with the IVUS unit acting as the guide. The fenestrations were balloon dilated and stented to support the true lumen.
RESULTS: Time to effective re-entry ranged from 6 to 10 minutes (mean 7) in the CTOs; antegrade flow was restored in all 7 CTOs, and the patients were free of ischemic symptoms at up to 8-month follow-up. In the aortic dissection cases, the fenestrations equalized pressures between the lumens and restored flow into the compromised vessels. There were no complications related to the use of this device in any of the 10 patients.
CONCLUSIONS: Our preliminary results demonstrate the feasibility of using this catheter-based system for subintimal recanalization with controlled re-entry in CTOs and for aortic flap fenestrations in aortic dissections. This approach can improve the technical success rate, reduce the time of the procedure, and minimize potential complications.