MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1136/gut.2009.177774

Медицинская библиотека · Gut · 2009

The feasibility of wireless capsule endoscopy in detecting small intestinal pathology in children under the age of 8 years: a multicentre European study.

Fritscher-Ravens A, Scherbakov P, Bufler P, Torroni F, Ruuska T, Nuutinen H, Thomson M, Tabbers M, Milla P

Оценочное исследованиеСтатьяМногоцентровое исследованиеПеревод в очереди

Аннотация

OBJECTIVE

To systematically evaluate the feasibility and methodology to carry out wireless capsule endoscopy (WCE) in children <8 years to define small intestinal pathology.

DESIGN

Prospective European multicentre study with negative prior investigation.

PATIENTS AND INTERVENTIONS: 83 children aged 1.5-7.9 years were recruited. Initially, all were offered "swallowing" (Group 1) for capsule introduction. If this failed endoscopic placement (Group 2) was used and the Roth net, Advance or custom-made introducers were compared.

OUTCOME MEASURES: Primary endpoint: to determine pathology; secondary endpoint: comparison of capsule introduction methods.

RESULTS

Capsule introduction: 20 (24%) children aged 4.0-7.9 years (mean, 6.9 years; 14 male) comprising Group 1 were older (p<0.025) than 63 (76%) aged 1.5-7.9 years (mean, 5.25 years; 30 male) forming Group 2.

COMPLICATIONS: Roth net mucosal trauma in 50%; no others occurred. The available recording apparatus was inappropriate for those <3 years.

INDICATIONS: gastrointestinal bleeding: n = 30 (16 positive findings: four ulcerative jejunitis, four polyps, two angiodysplasia, two blue rubber blebs, two Meckel's diverticula, one anastomotic ulcer, one reduplication); suspected Crohn's disease: n = 20 (11 had Crohn's disease); abdominal pain: n = 12 (six positive findings: three Crohn's disease, two lymphonodular hyperplasia, one blue rubber bleb); protein loss: n = 9 (four lymphangectasia); malabsorption: n = 12 (seven positive findings: six enteropathy, one ascaris). No abnormalities overall: 45%.

CONCLUSION

WCE is feasible and safe down to the age of 1.5 years. 20 children >4 years swallowed the capsule. The Advance introducer proved superior for endoscopic placement. The pathologies encountered showed age specificity and, unlike in adolescents, obscure gastrointestinal bleeding was the commonest indication.

Для цитирования: Fritscher-Ravens A, Scherbakov P, Bufler P, Torroni F, Ruuska T, Nuutinen H, Thomson M, Tabbers M, Milla P. The feasibility of wireless capsule endoscopy in detecting small intestinal pathology in children under the age of 8 years: a multicentre European study.. Gut. 2009. DOI: 10.1136/gut.2009.177774.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.