DOI 10.1038/s41433-026-04483-4
Multicentre study comparing ab-interno canaloplasty and trabecular micro-bypass stent in primary open-angle glaucoma.
Аннотация
PURPOSE: To compare canaloplasty and trabecular micro-bypass surgery outcomes in primary open-angle glaucoma (POAG).
METHODS
Ambispective study using data from the International Glaucoma Surgery Registry (IGSR) to evaluate mild-to-moderate POAG patients who underwent iTrack ab-interno canaloplasty (Nova Eye Medical, USA) (prospective cohort) or iStent trabecular micro-bypass implantation (Glaukos, USA) (retrospective cohort), with or without concomitant phacoemulsification, and ≥12 months of follow-up. Primary outcomes were intraocular pressure (IOP), medication usage, and surgical success as defined by the American Academy of Ophthalmology (2024).
RESULTS
The study included 339 eyes (iStent: n = 115; iTrack: n = 224) of which ≥94% underwent concomitant phacoemulsification (iStent: n = 109, iTrack: n = 210). There were nonsignificant differences in baseline IOP (p = 0.417) and medications (p = 0.741) between groups. At last follow-up, mean IOP (mmHg) and medication usage decreased from 17.3 ± 4.2 and 2.0 ± 1.1 at baseline to 14.2 ± 3.5 and 1.3 ± 1.1 in the iStent group (p < 0.001; mean follow-up: 27.2 ± 14.5 months), and from 16.9 ± 5.0 and 2.0 ± 1.1 at baseline to 14.3 ± 3.4 and 1.1 ± 1.3 in the iTrack group (p < 0.001; mean follow-up: 20.3 ± 7.7 months). Both groups showed no significant differences in reduction of IOP (p = 0.422) and medications (p = 0.211). More eyes were medication-free in the iTrack group (42% vs 29%; p = 0.029). Success was achieved in 61% of eyes in both groups (p = 1.000). Postoperatively, both groups demonstrated infrequent and self-limited complications, no sight-threatening events, and low reoperation rates.
CONCLUSION
In POAG, iTrack canaloplasty and iStent implantation showed no statistically significant differences in effectiveness outcomes. Both procedures had favourable safety profiles with limited additional glaucoma surgeries. More canaloplasty eyes were medication-free compared to stent eyes.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.