m+Medelevator.RU
← Поиск публикаций
Journal of neuro-ophthalmology : the official journal of the North American Neuro-Ophthalmology Society · 2024

Optic Nerve T2 Signal Intensity and Caliber Reflect Clinical Severity in Genetic Optic Atrophy.

СтатьяПоддержка NIH: внешняя программаНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Nagy M Aurel, Cunnane Mary E, Juliano Amy F, Wiggs Janey L, Caruso Paul A, Gaier Eric D

Аннотация

BACKGROUND: Genetic optic atrophies comprise phenotypically heterogenous disorders of mitochondrial function. We aimed to correlate quantitative neuroimaging findings of the optic nerves in these disorders with clinical measures.

METHODS: From a retrospective database of 111 patients with bilateral optic atrophy referred for genetic testing, 15 patients diagnosed with nonglaucomatous optic atrophy of genetic origin (7 patients with pathogenic variants in OPA1 , 3 patients with Wolfram syndrome, and 5 patients with Leber hereditary optic neuropathy) who had accessible magnetic resonance (MR) images of the orbits and/or brain were analyzed. The primary outcome measures of T2 short Tau inversion recovery (STIR) signal and optic nerve caliber were quantified according to a standardized protocol, normalized to internal standards, and compared between cases and controls. Inter-rater reliability was assessed and clinical features were analyzed according to MRI features.

RESULTS: Compared with control patients, the 15 genetic optic atrophy patients demonstrated significantly increased T2 STIR signal (fold-change 1.6, P = 0.0016) and decreased optic nerve caliber (fold-change 0.72, P = 0.00012) after internal normalization. These metrics were reliable (inter-reader reliability correlation coefficients of 0.98 [ P = 0.00036] and 0.74 [ P = 0.0025] for normalized STIR and nerve caliber, respectively) and significantly correlated with visual acuity, cup-to-disc ratio, and visual field testing.

CONCLUSIONS: Normalized optic nerve STIR signal and optic nerve caliber significantly correlate with visual acuity, cup-to-disc ratio, and perimetric performance in patients with genetic optic atrophy. A formalized protocol to characterize these differences on MRI may help to guide accurate and expedient diagnostic evaluation.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты