m+Medelevator.RU
← Поиск публикаций
Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB) · 2025

Simultaneous attenuation and scatter correction of PET data in the image: quantitative and clinical assessment of image-to-image deep learning models.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Elkayee Dehno Avishan, Ghafarian Pardis, Arabi Hossein, Ay Mohammad Reza

Аннотация

BACKGROUND: Positron Emission Tomography (PET) non-invasively assesses body metabolism but requires correction for photon attenuation and scatter.

PURPOSE: This study aims to convert non-attenuation scatter corrected (NASC) brain PET/CT images to measured attenuation and scatter corrected (MASC) images using deep learning algorithms.

METHODS: In this study, brain PET/CT (18F-FDG) images of 125 patients diagnosed with epilepsy disorder were used. Two convolutional neural networks, UNET and CGAN, were implemented to take 2D-NASC inputs and generate MASC images. For a precise evaluation, segmentation of 83 brain regions and the calculation of 19 radiomic features for each region were performed, and paired sample t-test was conducted for each region to determine significant differences between the predicted and ground-truth images. Clinical evaluation was performed by nuclear medicine physicians.

RESULTS: The mean Peak Signal-to-Noise Ratio (PSNR), Structural Similarity Index Measure (SSIM), and Root Mean Square Error (RMSE) were 41.55 ± 3.55 (dB), 0.997 ± 0.002, and 294.8 ± 131.0 (Bq/ml) for the CGAN model, and 40.70 ± 3.84 (dB), 0.996 ± 0.003, and 327.6 ± 163.8 (Bq/ml) for the UNET model, respectively. Among 1,577 paired values of radiomic features in different brain regions of test set, only 126 (CGAN) and 156 (UNET) values showed significant differences from the corresponding MASC values, indicating that the majority of radiomic features were well preserved while still highlighting subtle textural variations. In clinical evaluation, the UNET and CGAN models demonstrated strong performance in visual quality assessment.

CONCLUSION: Direct attenuation and scatter correction using both convolutional deep networks is a promising approach for brain PET images, when CT is not available.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты