MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.clae.2026.102636

Медицинская библиотека · Contact lens & anterior eye : the journal of the British Contact Lens Association · 2026

Comparing the short-term effects of wearing hydrogel and silicone hydrogel soft contact lenses on the bulbar conjunctival microvasculature and tear film.

Sun Yiran, Xu Zhiqiang, Shen Jiahui, Xia Jiahui, Lu Fan, Hu Liang

СтатьяРандомизированное исследованиеСравнительное исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

PURPOSE: To compare the short-term effects of etafilcon A hydrogel and senofilcon A silicone hydrogel soft contact lenses (SCLs) on the ocular surface.

METHODS

This prospective, double-masked, randomised crossover study required 20 participants to wear etafilcon A hydrogel and senofilcon A silicone hydrogel SCLs for seven days each, separated by a two-week washout period. Ocular examinations were conducted at baseline, and on day 1 and day 7 of lens wear. Bulbar conjunctival microvasculature assessment included vessel diameter (D), axial blood flow velocity (Va), cross-sectional blood flow velocity (Vs), blood flow volume (Q), and monofractal dimension (Dbox). Tear film analysis comprised tear meniscus height (TMH), first noninvasive tear break-up time (f-NIBUT), and average noninvasive tear break-up time (av-NIBUT). Participants completed the Ocular Surface Disease Index (OSDI) questionnaire at baseline and day 7 and the Visual Analogue Scale (VAS) on day 1 and day 7.

RESULTS

At baseline, no significant differences were observed between hydrogel and silicone hydrogel SCLs. On day 1 and day 7, both SCLs demonstrated increased Va, Vs, and Q, and reduced TMH, compared with baseline (p < 0.05). Silicone hydrogel SCLs exhibited higher Va, Vs, and Q values on day 1 (p < 0.05), while hydrogel SCLs showed shorter f-NIBUT on day 7 (p < 0.05). Both SCLs displayed increased OSDI and VAS scores over time (p < 0.05), with silicone hydrogel SCLs yielding higher VAS scores than hydrogel SCLs on day 7 (p < 0.05). Univariate analysis suggested that lens wear time (β = 5.1, p = 0.010), lens material (β = 4.2, p = 0.032), Va (β = 4870, p = 0.037) and Vs (β = -6586, p = 0.039) were significantly associated with VAS scores; however, only lens wear time and lens material remained significant in the multivariable model.

CONCLUSIONS

After seven days wear, etafilcon A hydrogel SCLs were associated with greater tear film instability, while senofilcon A silicone hydrogel SCLs resulted in greater conjunctival hyperaemia and more pronounced subjective discomfort.

Для цитирования: Sun Yiran, Xu Zhiqiang, Shen Jiahui, Xia Jiahui, Lu Fan, Hu Liang. Comparing the short-term effects of wearing hydrogel and silicone hydrogel soft contact lenses on the bulbar conjunctival microvasculature and tear film.. Contact lens & anterior eye : the journal of the British Contact Lens Association. 2026. DOI: 10.1016/j.clae.2026.102636.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.