[Chinese expert consensus on the clinical diagnosis and treatment of autosomal dominant optic atrophy (2024)].

Ophthalmology Group of China Alliance for Rare Diseases/Beijing Society of Rare Disease Clinical Care and Accessibility, Neuro-ophthalmology Group of Ophthalmology Branch of Chinese Medical Association

Аннотация на английскомСтатьяConsensus StatementПеревод в очереди

Аннотация

Autosomal dominant optic atrophy (ADOA) primarily affects retinal ganglion cells and their axons, resulting in varying degrees of central vision loss from childhood. Due to the rarity of ADOA in clinical practice, Chinese ophthalmologists currently lack sufficient understanding of the disease and experience non-standardized diagnostic procedures and high clinical and genetic misdiagnosis rates. To address these issues, the Ophthalmology Group of China Alliance for Rare Diseases/Beijing Society of Rare Disease Clinical Care and Accessibility and the Neuro-ophthalmology Group of Ophthalmology Branch of Chinese Medical Association have established an expert panel to form consensus opinions based on extensive discussions. This consensus would enhance the knowledge and diagnostic capabilities of Chinese clinicians regarding ADOA and promote awareness of related treatment principles and genetic counseling.

Для цитирования: Ophthalmology Group of China Alliance for Rare Diseases/Beijing Society of Rare Disease Clinical Care and Accessibility, Neuro-ophthalmology Group of Ophthalmology Branch of Chinese Medical Association. [Chinese expert consensus on the clinical diagnosis and treatment of autosomal dominant optic atrophy (2024)].. [Zhonghua yan ke za zhi] Chinese journal of ophthalmology. 2024. DOI: 10.3760/cma.j.cn112142-20231225-00308.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.