MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.clon.2025.103796

Медицинская библиотека · Clinical oncology (Royal College of Radiologists (Great Britain)) · 2025

Geometric and Dosimetric Evaluation of a RayStation Deep Learning Model for Auto-Segmentation of Organs at Risk in a Real-World Head and Neck Cancer Dataset.

Sharma D, Singh G, Burela N, Gayen S, Aishwarya G, Nangia S

СтатьяПеревод в очереди

Аннотация

AIMS: To assess geometric accuracy and dosimetric impact of a deep learning segmentation (DLS) model on a large, diverse dataset of head and neck cancer (HNC) patients treated with intensity-modulated proton therapy (IMPT).

MATERIALS AND

METHODS

A 3D U-Net-based DLS model was applied to CT datasets of 124 HNC patients treated with IMPT at 50.4-70.0 GyRBE. Thirty organs-at-risk (OARs), delineated manually (GT-OARs) were analysed for similarity metrics with auto-segmented OARs, without (DLS-nonedited) and with (DLS-edited) manual correction, using volume, Dice similarity coefficient (DSC), and Hausdorff distance (HD). Dosimetric impact of auto-segmentation error was assessed as absolute dose difference of mean (ΔDmean) and maximum (ΔDmax).

RESULTS

The cohort includes patients with postoperative (47.6%), flap reconstruction (12.1%), mouth bites (79.8%), dental implants (54.8%), and surgical implants (3.2%). DLS failed in 11 patients with significant anatomical challenges and artifact. Compared with GT-OARs, DLS-nonedited under-segmented 11/12 Gr-A (central nervous system, arteries, bone) (p < 0.05) and over-segmented 13/18 Gr-B (glandular, digestive, airways) OARs. DSC scores were good (>0.8), intermediate (0.6-0.8), intermediate-poor (0.5-0.6), and poor (<0.5) in 12, 6, 4, and 8 OARs. HD were good (<4mm), intermediate (4-6mm), poor (6-8mm), and very poor (>8mm) in 5, 7, 4, and 14 OARs. Compared with manually corrected, DLS-edited OARs, all DLS-nonedited OARs demonstrated excellent similarity with DSC>0.8 and HD<4mm. On average, auto-segmentation took 2.51 minutes, while correction took 6.24 minutes. The mean values of ΔDmean and ΔDmax were within ±300 and ±3 cGyRBE, except for oesophagus and larynx, where the mean ΔDmean increases up to 837.14 cGyRBE.

CONCLUSION

Patient posture, nonbiological materials, and anatomical deformities influence DLS accuracy. The model's overall performance is adequate and efficient with skilled manual editing needed for few OARs.

Для цитирования: Sharma D, Singh G, Burela N, Gayen S, Aishwarya G, Nangia S. Geometric and Dosimetric Evaluation of a RayStation Deep Learning Model for Auto-Segmentation of Organs at Risk in a Real-World Head and Neck Cancer Dataset.. Clinical oncology (Royal College of Radiologists (Great Britain)). 2025. DOI: 10.1016/j.clon.2025.103796.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.