DOI 10.1016/j.athoracsur.2018.11.066

Медицинская библиотека · The Annals of thoracic surgery · 2018

What Is the Potential of Tissue-Engineered Pulmonary Valves in Children?

Huygens Simone A, Rutten-van Mölken Maureen P M H, Noruzi Anahita, Etnel Jonathan R G, Corro Ramos Isaac, Bouten Carlijn V C, Kluin Jolanda, Takkenberg Johanna J M

СтатьяМетаанализПоддержка исследования: вне правительства СШАСистематический обзорПеревод в очереди

Аннотация

BACKGROUND

As a living heart valve substitute with growth potential and improved durability, tissue-engineered heart valves (TEHVs) may prevent reinterventions that are currently often needed in children with congenital heart disease. We performed early health technology assessment to assess the potential cost-effectiveness of TEHVs in children requiring right ventricular outflow tract reconstruction (RVOTR).

METHODS

A systematic review and meta-analysis was conducted of studies reporting clinical outcome after RVOTR with existing heart valve substitutes in children (mean age ≤12 years or maximum age ≤21 years) published between January 1, 2000, and May 2, 2018. Using a patient-level simulation model, costs and effects of RVOTR with TEHVs compared with existing heart valve substitutes were assessed from a health care perspective applying a 10-year time horizon. Improvements in performance of TEHVs, divided in durability, thrombogenicity, and infection resistance, were explored to estimate quality-adjusted life year (QALY) gain, cost reduction, headroom, and budget impact associated with TEHVs.

RESULTS

Five-year freedom from reintervention after RVOTR with existing heart valve substitutes was 46.1% in patients less than or equal to 2 years of age and 81.1% in patients greater than 2 years of age. Improvements in durability had the highest impact on QALYs and costs. In the improved TEHV performance scenario (durability ≥5 years and -50% other valve-related events), QALY gain was 0.074 and cost reduction was €10,378 per patient, translating to maximum additional costs of €11,856 per TEHV compared with existing heart valve substitutes.

CONCLUSIONS

This study showed that there is room for improvement in clinical outcomes in children requiring RVOTR. If TEHVs result in improved clinical outcomes, they are expected to be cost-effective compared with existing heart valve substitutes.

Для цитирования: Huygens Simone A, Rutten-van Mölken Maureen P M H, Noruzi Anahita, Etnel Jonathan R G, Corro Ramos Isaac, Bouten Carlijn V C, Kluin Jolanda, Takkenberg Johanna J M. What Is the Potential of Tissue-Engineered Pulmonary Valves in Children?. The Annals of thoracic surgery. 2018. DOI: 10.1016/j.athoracsur.2018.11.066.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.