MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.acvd.2022.01.003

Медицинская библиотека · Archives of cardiovascular diseases · 2022

Transcatheter closure of tubular patent ductus arteriosus using muscular ventricular septal defect devices in infants and small children with congestive heart failure.

Salam Abdul, Bautista-Rodriguez Carles, Karsenty Clement, Bouvaist Helene, Piccinelli Enrico, Fraisse Alain

СтатьяНаблюдательное исследованиеПеревод в очереди

Аннотация

BACKGROUND

Transcatheter closure of a patent ductus arteriosus in children is widely performed to reduce symptoms and decrease the risk of endocarditis. Most arterial ducts are closed successfully with dedicated devices. However, in a tubular or "type C" patent ductus arteriosus with congestive heart failure, the occlusion is more challenging with these devices, with a higher risk of complications, such as aortic or left pulmonary stenosis and device embolization.

AIM: To report our experience with muscular ventricular septal defect devices for patent ductus arteriosus occlusion in small children.

METHODS

Retrospective observational series of patients weighing<10kg, with a tubular patent ductus arteriosus (typeC) and congestive heart failure, who underwent transcatheter closure with a muscular ventricular septal defect device between 2017 and 2019.

RESULTS

Eight patients were included. The mean age and weight at closure were 6.3 months (range 1-18 months) and 5.3kg (range 2.4-8.2kg), respectively. All patent ductus arteriosus were occluded successfully using Occlutech® (N=3) or Amplatzer® (N=5) muscular ventricular septal defect devices. In four cases, the muscular ventricular septal defect device was used after failure to close the patent ductus arteriosus with a dedicated patent ductus arteriosus device. Two patients had mild left pulmonary artery stenosis, with a maximum velocity on continuous Doppler of 3m/s and 2.7m/s, respectively. After a mean follow-up of 28 months (range 14-41 months), all patients were asymptomatic with excellent results. The mild pulmonary stenosis improved, with a maximum velocity of 2.3m/s in both patients.

CONCLUSIONS

Closure of tubular patent ductus arteriosus in small children with congestive heart failure using a muscular ventricular septal defect device is safe in this preliminary experience. Further studies with more patients are warranted.

Для цитирования: Salam Abdul, Bautista-Rodriguez Carles, Karsenty Clement, Bouvaist Helene, Piccinelli Enrico, Fraisse Alain. Transcatheter closure of tubular patent ductus arteriosus using muscular ventricular septal defect devices in infants and small children with congestive heart failure.. Archives of cardiovascular diseases. 2022. DOI: 10.1016/j.acvd.2022.01.003.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.