Intrathecal Gadolinium-Enhanced MR Cisternography Improves the Detection of Skull Base CSF Leaks.

Totten Douglas J, Koontz Nicholas A, Elms Hunter L, Cumpston Evan C, Schneider William, Whitted Cody, Tann Mark, Booth Kevin T, Mosier Kristine M, Nelson Rick F

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

To compare the efficacy of contrast enhanced magnetic resonance cisternography (CE-MRC), computed tomography cisternography (CTC), and single-photon emission computed tomography (SPECT-CT) radionuclide cisternography (RNC) in detection of skull base cerebrospinal fluid (CSF) leaks.

STUDY

DESIGN

Retrospective cohort study.

SETTING

Tertiary referral center.

PATIENTS: Adult patients with suspected anterior skull base (ASB) or lateral skull base (LSB) CSF leak who underwent CE-MRC, CTC, and/or SPECT-CT RNC to assess for CSF leak from 2018 to 2024.

MAIN OUTCOME MEASURES: Evidence of CSF leak on single or multiple cisternogram types.

RESULTS

Fifty patients (74% female) had a mean (standard deviation) age of 50 (17) years and a median BMI of 34 (IQR, 28-42) kg/m 2 . Nineteen patients had a surgically or laboratory-confirmed CSF leak. Of these, 78% were spontaneous CSF leaks. There were no false-positive tests for any mode of cisternograms. CT cisternograms had a sensitivity of 53% (ASB: 86%, LSB: 33%) compared with a sensitivity of 90% (ASB: 100%, LSB: 86%) for CE-MR cisternograms and 67% (ASB: 100%, LSB: 33%) for SPECT-CT RN cisternograms.

CONCLUSIONS

CE-MRC appears to be more sensitive than CTC and SPECT-CT RNC in detecting skull base CSF leaks, particularly in the lateral skull base. CE-MRC should be used when appropriate in combination with high-resolution CT to assess for CSF leaks when there is a high index of suspicion with inconclusive beta-2 transferrin testing.

LEVEL OF EVIDENCE: 4.

Для цитирования: Totten Douglas J, Koontz Nicholas A, Elms Hunter L, Cumpston Evan C, Schneider William, Whitted Cody, Tann Mark, Booth Kevin T, Mosier Kristine M, Nelson Rick F. Intrathecal Gadolinium-Enhanced MR Cisternography Improves the Detection of Skull Base CSF Leaks.. Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology. 2025. DOI: 10.1097/mao.0000000000004601.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.