MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s10554-024-03073-3

Медицинская библиотека · The international journal of cardiovascular imaging · 2024

Discordance interpretation of left ventricular size between echocardiography and cardiac magnetic resonance in pediatric patients with aortic/mitral regurgitation.

Barros Anastasia, Udine Michelle, Spurney Chris, Olivieri Laura, Loke Yue-Hin

СтатьяСравнительное исследованиеПеревод в очереди

Аннотация

PURPOSE: This study investigated discordance between echocardiography (echo) and cardiac magnetic resonance (CMR) measurements of the left ventricle (LV) in pediatric patients with aortic and/or mitral regurgitation (AR/MR).

METHODS

Retrospective cohort study of pediatric patients. The cohorts were comprised of patients with AR/MR vs. non-AR/MR. Left ventricular end diastolic volume (LVEDV) by CMR and left ventricular internal diameter diastolic (LVIDd) by echo were obtained from clinical reports then echo images were reviewed to remeasure LVEDV by bullet method. Left ventricular internal diameter systolic (LVIDs) and left ventricular ejection fraction (LVEF) measurements by echo and LVEF by CMR were obtained from clinical reports. Fractional shortening (FS%) was recalculated. Z-scores were calculated using normative data. Correlation between echo and CMR LV measurements was assessed using correlation coefficients. Bland-Altman plots assessed bias between imaging modalities. Receiver operator characteristic (ROC) analysis was performed for detection of LV enlargement and LV dysfunction.

RESULTS

AR/MR patients had greater discrepancy in LV size interpretation by Z-score compared to non-AR/MR patients. This discrepancy persisted when the bullet method short axis measurements were incorporated. There was negative bias in echo-based measurements compared to CMR. The diagnostic performance of echo in identifying moderate LV enlargement was worse for AR/MR pediatrics patients.

CONCLUSION

The discordant interpretation of LV size by echo compared to CMR is worse in pediatric patients with AR/MR when compared to patients without AR/MR even when short axis measurements are incorporated. This finding suggests non-uniform geometrical changes in the LV as it enlarges due to AR/MR.

Для цитирования: Barros Anastasia, Udine Michelle, Spurney Chris, Olivieri Laura, Loke Yue-Hin. Discordance interpretation of left ventricular size between echocardiography and cardiac magnetic resonance in pediatric patients with aortic/mitral regurgitation.. The international journal of cardiovascular imaging. 2024. DOI: 10.1007/s10554-024-03073-3.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.