DOI 10.1097/00004728-200207000-00027

Медицинская библиотека · Journal of computer assisted tomography · 2002

Comparison of 1.5 and 8 tesla high-resolution magnetic resonance imaging of lacunar infarcts.

Chakeres Donald W, Abduljalil Amir M, Novak Peter, Novak Vera

Клинический случайСравнительное исследованиеОценочное исследованиеСтатьяПоддержка исследования: вне правительства СШАПоддержка службы здравоохранения СШАПеревод в очереди

Аннотация

PURPOSE: We present a case report comparing 1.5 fast spin-echo (FSE) and high-resolution 8 Tesla (T) gradient echo (GE) MRI of a patient with multiple lacunar infarcts.

METHODS

A 51-year-old man with a history of previous lacunar infarctions was studied with two-dimensional Fourier transform axial 8 T GE MRI using the following parameters: 3 mm thick slices skip 3 mm, flip-angle approximately 20 degrees, TR 800 milliseconds, TE 12 milliseconds, 1024 x 1024 matrix, field of view (FOV) 20 cm, and bandwidth 50 kHz. These images were then compared with routine clinical 1.5 T T2-weighted FSE images with 5 mm thick sections, 256 x 256, FOV 20, TR 5650, TE 102, and 16 echo train length.

RESULTS

The majority of the infarctions were seen as areas of high signal intensity on both the 1.5 and 8 T images. They were seen in the corona radiata or the basal ganglia. More lesions were seen on the 8 T images. Low intensity signal was best demonstrated on the 8 T images at segments of the periphery of a few of the larger infarcts. There were a few small punctate low signal intensity regions localized at the termination of some of the microvessels on the 8 T images only. The foci of decreased signal intensity in regions of chronic hemorrhage appeared larger on the 8 T images compared with the 1.5 T images. The 8 T images demonstrated direct visualization of many small vessels, primarily in the deep white matter, which were not visible on the 1.5 T images. On the 8 T images, some of the infarcts appeared to be located between the medullary veins of the deep white matter.

CONCLUSION

This case report indicates that GE 8 T images demonstrate more infarctions compared with the FSE 1.5 T images. It is possible to simultaneously identify the microvessels of the brain, small foci of hemorrhage, and lacunar infarctions using 8 T MRI.

Для цитирования: Chakeres Donald W, Abduljalil Amir M, Novak Peter, Novak Vera. Comparison of 1.5 and 8 tesla high-resolution magnetic resonance imaging of lacunar infarcts.. Journal of computer assisted tomography. 2002. DOI: 10.1097/00004728-200207000-00027.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.